Installation data, Commissioning information, Scope of supply – NORD Drivesystems TI043_278910340 User Manual
Page 2: Connection kit, Connections, Tools
Getriebebau NORD GmbH & Co. KG
Rudolf-Diesel-Straße 1 · D-22941 Bargteheide
Tel.: +49 45 32 - 40 10 · Fax: +49 45 32 - 40 12 53 · www.nord.com
Connection kit
WK 4/2/4*680 Ohm
TI 043 278910340
2/2
1.0 First
edition
06.07.10
Rck
Version Change Datum
Name
Document
Page
Connections:
The electrical connection of the encoder and the frequency inverter is via screw terminals according to the table (see illustration
above).
Function
Wire colour: HTL
encoder
Terminal number
Connection kit WK 4/2/4*680 Ohm
Terminal number,
frequency inverter
Supply voltage 10 - 30V DC
brown / green
1
42 (VO 15VDC) or 44 (VO 24VDC)
0V / GND
white / green
2
40 (GND)
Track A
brown
3
51 (ENC A+)
Track A /
green
4
52 (ENC A-)
Track B
grey
5
53 (ENC B+)
Track B /
pink
6
54 (ENC B-)
Tools:
Slot-head screwdriver 0.6 x 3.5
Installation data:
Dimensions:
[mm]
H63 x W38.5 x D48
Mounting:
Snap-on rail mounting (35mm snap-on DIN rail / TS35)
Commissioning information:
The connection kit is delivered as individual parts and must be
correctly mounted on a snap-on DIN rail on site. The following
mounting sequence (starting on the left) must be observed:
1. 2 x through terminal (WK4/U/VO)
2. 4 x fuse terminal (WK 4TKG/U/VO),
3. 1 x Cover plate (AP 4 TK/VO).
The 4 x enclosed diode plugs must be mounted on the insulated
base terminals (snap-on). The enclosed labelling strips must
also be attached.
The connection between the frequency inverter and the
connection kit should be as short as possible. The use of a shielded connection cable is recommended. The shield must be
well earthed at both ends. The shield of the encoder cable must also be connected to PE.
Scope of supply:
Item
Name
Name
Number
1
Labelling strip (1 ... 6)
9705A/6/10B 1-10 horizontal
1
2
Diode plug
680 Ohm +/- 11% /0.6W
4
3
Through terminal
WK 4/U/VO
2
4
Fuse terminal
WK 4 TKG/U/VO
4
5
Cover plate
AP 4 TK / VO
1