Control box – SK POT1-2
TI 278910140 - 3313
3
Frequency inverter interfaces
Frequency inverter
SK POT1-…
SK 180E
SK 190E
SK 2x0E
SK 2x5E with
SK 5xxE
Function
SK CU4-IOE
SK TU4-IOE
Connector terminal
white
43
44
23
X5:42 or 44
VI (+15 V or +24 V)
brown
21
C1
19
X5:21
ON right
green
22
C2
25
X5:22
ON left
yellow
12
12+13
5+7
X4:12
AGND
grey
14
14
3
X4:14
Analog +
pink
11
11
1
X4:11
Analog Ref. +10 V
black *
12
12
8
X4:12
Shield *
* not with SK POT1-1
Pos : 6 /T ec hnis che Inf or mationen/ Bedi enboxen [SK POT 1-.. .]/ Anschl uss SK POT 1-.. . an N et zt eil [nur SK 2x5E] @ 3\ mod_1368000909219_388. doc x @ 64811 @ @ 1
*Only for SK 2x5E:
Alternative connection of the control box to an SK CU4-24V-… mains unit
Frequency inverter
SK 205E-.../SK 215E-...
C
ont
ro
l t
er
m
in
al
bar
44
40
.
.
21
22
23
24
.
.
.
L1 - L2/N - L3
115/230/400V
SK CU4-24V-...
L1 - L2/N
115/230/400V
24V=
GND
10V=
AGND
0-10V
R
L
0-100%
1/3~ 115/230/400V + PE
Control terminal bar
44 40 44 ... 11 14 12 B1
Switch
Potentiometer 10kOhm
SK POT1-…
gn
bn
ws
rs
gr gb
If this connection method is used, one of the following variants must be selected for the configuration
of the control box. The configuration is carried out on the frequency inverter.
Version
Configuration via
Setting
1
DIP switch
DIP3
Off
DIP4
On
DIP5
Off
2
Parameterisation
P400 [-07]
1
P420 [-01]
1
P400 [-02]
2
P400 [-03]
26