Electrical data 230v, Electrical data 400v – NORD Drivesystems BU0560 User Manual
Page 4
NORDAC SK 500E - ERS Information
Electrical data
4
Subject to technical amendments
BU0560_ERS_GB-0512
The "ERS" special versions are only available for the following devices/powers:
SK
500E-750-323-A-ERS
275410076
SK
511E-750-323-A-ERS
275770076
SK 500E-111-323-A-ERS 275410111
SK
500E-221-323-A-ERS
275410221
SK
511E-221-323-A-ERS
275770221
SK 500E-111-340-A-ERS 275420111
SK 500E-301-340-A-ERS 275420301
Electrical data 230V
Size 1 / 2
Device type:
SK 5xxE…
-750-323-A-ERS
-111-323-A-ERS
-221-323-A-ERS
Nominal motor power
(4-pole standard motor)
230V
0.75 kW
1.1 kW
2.2 kW
240V
1 hp
1½ hp
3 hp
Mains phases
Number
1/3 AC
Mains voltage
200 - 240 V, ±10 %, 47 ... 63 Hz
Output voltage
3 AC
0 - mains voltage
Nominal output current
rms [A]
4.0
5.5
9.0
Min. brake resistor
Accessories
100
75
43
Typical input current
1 / 3 AC
rms [A]
8.7 / 5.6
12.0 / 7.7
19.6 / 13.3
Rec. mains fuse
1 / 3 AC
slow-blowing
16 A / 10 A
16 A / 16 A
25 A / 20 A
Type of ventilation
Free convection
Fan cooling, temperature controlled
Switching thresholds: ON ≈ 57°C OFF ≈ 47°C
Weight Approx.
[kg]
1.8
2.7
Electrical data 400V
Size 2 / 3
Device type:
SK 5xxE…
-111-340-A-ERS
-301-340-A-ERS
Nominal motor power
(4-pole standard motor)
400V
1.1 kW
3.0 kW
480V
1½ hp
4 hp
Mains phases
Number
3 AC
Mains voltage
380 … 480 V, -20% / +10 %, 47 ... 63 Hz
Output voltage
3 AC
0 - mains voltage
Nominal output current
rms [A]
3.1
7.5
Min. brake resistor
Accessories
220
91
Typical input current
1 / 3 AC
rms [A]
4.3 12.5
Rec. mains fuse
1 / 3 AC
slow-blowing
10 A
16 A
Type of ventilation
Fan cooling, temperature controlled
Switching thresholds: ON ≈ 57°C OFF ≈ 47°C
Weight Approx.
[kg]
1.8
2.7
Note:
Up to week of manufacture 48/08, SK 500E-111-340-A-ERS frequency inverters were produced with
free convection (without fan). Since week 49/08 a fan has also been incorporated in units of this size to
provide better dissipation of heat.