SMU-9000 User Manual
20
••••
Part IV: System Performance
SMU 9000-25U W/1 KHz Low Pass Filter
Offset: .040”
Range: .200”
Output: 10V
Target: Nickel Plated Aluminum
(2-3 mils of plating)
SMU 9000-25U PN 854291-004 Resolution
(Noise)
0
2
4
6
8
100
1000
10000
100000
1000000
Bandw idth, Hz
p-p noise, microinches
Figure 17. SMU 9000-25U Resolution
SMU 9000-25U PN 854291-004 Noise Density
0.000
0.050
0.100
0.150
0.200
0.250
100
1000
10000
100000
1000000
Bandw idth, Hz
p-p noise, microinches/root H
z
Figure 18. SMU 9000-25U Noise Density