Dwyer WE04 User Manual
W.e. anderson, a div. of dwyer instruments, inc
Series WE04 2-Piece Flanged Stainless Steel Ball Valve
Specifications - Installation and Operating Instructions
Bulletin V-WE04
The Series WE04 incorporates a full port
2-piece flanged SS ball valve for great
flow rates with minimal pressure drop.
The valve features a blowout proof stem
for added safety, reinforced PTFE seats
and seals for longer life, and a 316 SS
(ASTM
CF8M)
ball
for
better
performance. Actuators are direct
mounted creating a compact assembly
for tight spaces. Limit switches are able
to be mounted directly to the valves
allowing for remote position indication.
The Series WE04 can be configured with
either a pneumatic or electric actuator.
Electric actuators are available in
weatherproof or explosion-proof, a
variety of supply voltages, and two-
position or modulating control. Two-
position actuators use the supply voltage
to drive the valve open or closed, while
the modulating actuator accepts a 4 to 20
mA input for valve positioning. Actuators
feature thermal overload protection and
permanently lubricated gear train.
The pneumatic double acting actuator
uses an air supply to drive the valve open
and closed. The actuator has two supply
ports, with one driving the valve open,
and the other driving the valve closed.
Spring return pneumatic actuators use
the air supply to open the valve, and
internally loaded springs return the valve
to the closed position. Also available is
the SN solenoid valve to electrically
switch the air supply pressure between
the air supply ports for opening and
closing the valve. Actuators are
constructed of anodized and epoxy
coated aluminum for years of corrosion
free service.
SPECIFICATIONS
VALVE
Service: Compatible liquids and gases.
Body: 2-piece.
Line Sizes: 1/2 to 3˝ .
End Connections: 150# ANSI flange.
Pressure Limits: 20˝ Hg to 275 psi
(-0.7 to 19 bar).
Wetted Materials:
Body and ball: 316 SS (CF8M);
Stem: 316 SS;
Seat: RTFE/PTFE;
Seal, Washer, and Packing: PTFE.
Temperature Limits: -20 to 392°F
(-29 to 200°C).
Other Materials:
O-ring: Fluoroelastomer;
Handle: 304 SS;
Washer: 301 SS;
Stem Nut, Locking Device,
Gland Ring: 304 SS;
Handle Sleeve: PVC.
ACTUATORS
Pneumatic “DA” and “SR” Series
Type: DA series is double acting and
SR series is spring return (rack and
pinion).
Normal Supply Pressure:
DA: 40 to 115 psi (2.7 to 7.9 bar);
SR: 80 psi (5.5 bar).
Maximum Supply Pressure: 120 psi
(8.6 bar).
Air Connections:
DA01: 1/8˝ female NPT;
DA02 to DA04: 1/4˝ female NPT;
SR02 to SR06: 1/4˝ female NPT.
Housing Material: Anodized aluminum
body and epoxy coated aluminum end
caps.
Temperature Limits: -40 to 176°F (-40
to 80°C).
Accessory Mounting: NAMUR
standard.
Electric “TD” and “MD” Series
Power Requirements: 110 VAC,
220 VAC, 24 VAC OR 240 VDC (MD
models not available in 24 VDC) .
Power Consumption: See page 8.
Cycle Time (per 90°):
TD01: 4 s;
MD01: 10 s;
TD02 and MD02: 20 s.
Duty Rating: 85%.
Enclosure Rating: NEMA 4X (IP67).
Housing Material: Powder coated
aluminum.
Temperature Limits: -22 to 140°F
(-30 to 60°C).
Electrical Connection: 1/2˝ female
NPT.
Modulating Input: 4 to 20 mA.
Standard Features: Manual override,
position indicator, and TD models come
with two limit switches.
Electric “TI” and “MI” Series
Power Requirements: 110 VAC,
220 VAC, 24 VAC or 24 VAC.
Power Consumption: See page 8.
Cycle Time (per 90°):
TI01 and MI01: 2.5 s;
TI02 and MI02: 5 s;
TI03 and MI03: 5 s;
TI04 and MI04: 10 s;
TI05 and MI05: 15 s.
Duty Rating:
Two-Position:
TI01-TI05: 25%;
Modulating:
MI01-MI05: 75%.
Enclosure Rating: NEMA 7
.
Housing Material: Powder coated
aluminum.
Temperature Limits: -40 to 140°F
(-40 to 60°C).
Electrical Connection: 1/2˝ female
NPT.
Modulating Input: 4 to 20 mA.
Standard Features: Position indicator
and two limit switches.
WE04-DTD01-A
WE04-DHD00
WE04-DDA02-AA03
WE04-DDA02-NN09
WE04-CTI01-A
W.E. ANDERSON,
A DIV. OF DWYER INSTRUMENTS, INC.
P.O. BOX 373 • MICHIGAN CITY, INDIANA 46360 U.S.A.
Phone: 219/879-8000
www.dwyer-inst.com
Fax: 219/872-9057
e-mail: [email protected]