beautypg.com

Dwyer DPMA-4 User Manual

Dwyer instruments, inc, Series dpma-4 adjustable lcd digital panel meters, Bulletin g-63

background image

Series DPMA-4 Adjustable LCD Digital Panel Meters

Specifications - Installation and Operating Instructions

Bulletin G-63

DWYER INSTRUMENTS, INC.

Phone: 219/879-8000

www.dwyer-inst.com

P.O. BOX 373 • MICHIGAN CITY, INDIANA 46360, U.S.A. Fax: 219/872-9057

e-mail: [email protected]

Series DPMA-4 Adjustable LCD Digital Panel Meter offers a 3-1/2
digit display for easy viewing in a standard 1/8 DIN package. Unit
accepts 4 to 20 mA DC inputs with a wide bipolar span and zero
adjustment. Standard features include field selectable engineering units
and decimal point positions. Choose from red, amber, or green
segments for easy viewing at a distance. A 24 VDC power supply is
required for the operation of the backlight.

INSTALLATION
The Series DPMA-4 is designed to snap into a 3.62˝ (92 mm) W x 1.77˝
(45 mm) H panel cutout. No additional hardware is required.

WIRING
The unit is powered by a 4 to 20 mA loop and the screw terminal for
wiring is located on the back of the adder board marked with + SIG -. The
backlighting requires a 24 VDC power supply and should be connected
to terminals identified with +pwr-.

Note: If backlight supply is not loop supply, ground should be referenced
together.

SPECIFICATIONS
Input:
4 to 20 mA.
Input Impedance: 300Ω nominal.
Accuracy: ±(0.05% FS + 1 count).
Power Supply: Powered by control loop.
Backlight Power Supply: 24 VDC @ 35 mA typical.
Span and Zero: Adjustable (±1999 counts).
Display: 3-1/2 digits, 7 segments, 1˝ (25.4 mm) H.
Decimal Points: 3-position, user selectable.
Engineering Units: DPMA-XXX: °F, °C, %, PSI; DPMA-XXXP: V, A,
KW, PF.
Polarity: Automatic, “-” displayed.
Operating Temperature: 32 to 122°F (0 to 50°C).
Storage Temperature: -4 to 158°F (-20 to 70°C).
Mounting: Snap-in panel mount or clamp (gasket included).
Connection: Screw terminals.
Conversion Rate: 3 per second.
Warm-up: 10 minutes typical.
Weight: 4 oz (113.4 g).
Agency Approvals: RoHS.

TYPICAL LOOP CONNECTION

Figure 1

V

A

KW

PF

°F

°C

PSI

%

P Models

1-59/64

[49]

1-59/64

[49]

15/32

[12]

63/64

[25]

5/64

[1.9]

13/64

[5]

1-1/8

[28.5]

3-25/32

[96]

1-57/64

[48]

3-15/32

[88] REAR HOUSING

3-5/8

[92]

1-49/64

[45]

4-29/64

[113]

MOUNTING BRACKET

OUTLINE REAR VIEW

PANEL CUTOUT

FOR SNAP IN MOUNTING

(R.010 MAX) 4 PLCS [.25 mm]