Dwyer instruments, inc – Dwyer CDT User Manual
Page 4

MAINTENANCE/REpAIR
Upon final installation of the Series CDT and CDTR, no routine maintenance is
required. The Series CDT and CDTR are not field serviceable and should be
returned if repair is needed. Field repair should not be attempted and may void
warranty.
WARRANTY/RETURN
Refer to “Terms and Conditions of Sales” in our catalog and on our website. Contact
customer service to receive a Return Goods Authorization number before shipping
the product back for repair. Be sure to include a brief description of the problem
plus any additional application notes.
DWYER INSTRUMENTS, INC.
phone: 219/879-8000
www.dwyer-inst.com
p.O. BOX 373 • MICHIGAN CITY, INDIANA 46360, U.S.A.
fax: 219/872-9057
e-mail: [email protected]
©Copyright 2013 Dwyer Instruments, Inc.
Printed in U.S.A. 3/13
FR# 06-443800-20 Rev. 1
RESISTANCE VS TEMpERATURE TABLE
°C
-55
-50
-45
-40
-35
-30
-25
-20
-15
-10
-5
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
105
110
115
120
125
130
135
140
145
150
°f
-67.0
-58.0
-49.0
-40.0
-31.0
-22.0
-13.0
-4.0
5.0
14.0
23.0
32.0
41.0
50.0
59.0
68.0
77.0
86.0
95.0
104.0
113.0
122.0
131.0
140.0
149.0
158.0
167.0
176.0
185.0
194.0
203.0
212.0
221.0
230.0
239.0
248.0
257.0
266.0
275.0
284.0
293.0
302.0
Temperature
A
607800.00
441200.00
323600.00
239700.00
179200.00
135200.00
102900.00
78910.00
61020.00
47540.00
37310.00
29490.00
23460.00
18780.00
15130.00
12260.00
10000.00
8194.00
6752.00
5592.00
4655.00
3893.00
3271.00
2760.00
2339.00
1990.00
1700.00
1458.00
1255.00
1084.00
939.30
816.80
712.60
623.60
547.30
481.80
425.30
376.40
334.00
297.20
265.10
237.00
B
963849.00
670166.00
471985.00
336479.00
242681.00
176974.00
130421.00
97081.00
72957.00
55329.00
42327.00
32650.00
25392.00
19901.00
15712.00
12493.00
10000.00
8057.00
6531.00
5326.00
4368.00
3602.00
2986.00
2488.00
2083.00
1752.00
1480.00
1255.00
1070.00
915.50
786.60
678.60
587.60
510.60
445.30
389.60
341.90
301.00
265.80
235.30
208.90
186.10
C
289154.70
201049.80
141595.50
100943.70
72804.30
53092.20
39126.30
29124.30
21887.10
16598.70
12698.10
9795.00
7617.60
5970.30
4713.60
3747.90
3000.00
2417.10
1959.30
1597.80
1310.40
1080.60
895.80
746.40
624.90
525.60
444.00
376.50
321.00
274.65
235.98
203.58
176.28
153.18
133.59
116.88
102.57
90.30
79.74
70.59
62.67
55.83
D
78.32
80.31
82.29
84.27
86.25
88.22
90.19
92.16
94.12
96.09
98.04
100.00
101.95
103.90
105.85
107.79
109.74
111.67
113.61
115.54
117.47
119.40
121.32
123.24
125.16
127.08
128.99
130.90
132.80
134.71
136.61
138.51
140.40
142.29
144.18
146.07
147.95
149.83
151.71
153.58
155.46
157.33
E
783.2
803.1
822.9
842.7
862.5
882.2
901.9
921.6
941.2
960.9
980.4
1000.0
1019.5
1039.0
1058.5
1077.9
1097.4
1116.7
1136.1
1155.4
1174.7
1194.0
1213.2
1232.4
1251.6
1270.8
1289.9
1309.0
1328.0
1347.1
1366.1
1385.1
1404.0
1422.9
1441.8
1460.7
1479.5
1498.3
1517.1
1535.8
1554.6
1573.3
f
2394000.00
1646200.00
1145800.00
806800.00
574400.00
413400.00
300400.00
220600.00
163500.00
122280.00
92240.00
70160.00
53780.00
41560.00
32340.00
25360.00
20000.00
15892.00
12704.00
10216.00
8264.00
6722.00
5498.00
4520.00
3734.00
3100.00
2586.00
2166.00
1822.60
1540.00
1306.40
1112.60
951.00
815.80
702.20
606.40
525.60
N/A
N/A
N/A
N/A
N/A
Resistance Curves (in Ohms)
1
P1
SENS
2
CO
2
SENSOR
Series
Range
Configuration
CO
2
Output
Temperature
Output
Options
CDT -2
2
5
W
W
4
0
4
A
B
C
D
E
F
-LCD
LCD
RLY
NBC
4
4
Example: CDT-2W44-LCD
0 to 2000 ppm CO
2
range
0 to 5000 ppm CO
2
range
Wall
4 to 20 mA / 0 to (5 or 10) VDC
None
4 to 20 mA / 0 to (5 or 10) VDC
10 KΩ NTC thermistor type III
10 KΩ NTC thermistor type II
3 KΩ NTC thermistor
Pt100 Ω RTD
Pt1000 Ω RTD
20 KΩ NTC thermistor
LCD display
Relay
No buttons
figure 7: Calibration
figure 8: CDT Model Chart
figure 10: Elevation Chart
figure 11: Resistance vs Temperature
ft
0
400
800
1200
1600
2000
2400
2800
3200
3600
4000
4400
4800
5200
5600
6000
6400
6800
7200
7600
8000
8400
8800
9200
9600
10000
in Hg
29.92
29.50
29.10
28.69
28.29
27.90
27.51
27.13
26.76
26.39
26.02
25.66
25.30
24.95
24.60
24.26
23.93
23.60
23.27
22.94
22.63
22.31
22.00
21.70
21.40
21.40
m
0
100
200
300
400
500
600
700
800
900
1000
1100
1200
1300
1400
1500
1600
1700
1800
1900
2000
2100
2200
2300
2400
2500
hpa
1013
1002
990
979
968
957
946
935
924
914
904
893
883
873
863
853
844
834
824
815
806
797
787
779
770
761
US Customary Units
SI Units
Series
Range
Configuration
CO
2
Output
Temperature
Output
RH Output
Options
CDTR -2
2
5
W
W
A
0
A
B
C
D
E
F
-LCD
LCD
RLY
NBC
4
4
Example: CDTR-2W4A4-LCD
0 to 2000 ppm CO
2
range
0 to 5000 ppm CO
2
range
Wall
4 to 20 mA / 0 to (5 or 10) VDC
None
10 KΩ NTC thermistor type III
10 KΩ NTC thermistor type II
3 KΩ NTC thermistor
Pt100 Ω RTD
Pt1000 Ω RTD
20 KΩ NTC thermistor
4 to 20 mA / 0 to (5 or 10) VDC
LCD display
Relay
No buttons
4
4
figure 9: CDTR Model Chart