4.3

How To Install the Tubing and Fittings

Inlet Tubing - Locate the inlet fitting of the pump head. Remove the
tube nut. Push the clear PVC suction tubing onto the compression barb
of the fitting. Use the tube nut to secure the tube. Hand tighten only.

Footvalve/Strainer -Trim the inlet end of the suction tubing so that the
strainer will rest in a vertical position, approximately one inch from the
bottom of the solution tank. This will prevent sediment from clogging the
strainer. Loss of prime may occur if the footvalve is permitted to lay on
the bottom of the solution tank in a horizontal position. Slip the ceramic
weight over the end of the suction tube. Press the footvalve/strainer into
the end of the tube. Secure the ceramic weight to the strainer. Drop the
strainer into the solution tank.

Outlet Tubing - Locate the outlet fitting of the pump head, Remove the
tube nut. Push the rigid outlet (discharge) tubing onto the compression
barb of the fitting. Use the tube nut to secure the tube. Hand tighten
only.

Trim the other end of the outlet tube leaving only enough slack to
connect it to the Injection/Check valve Fitting . Increasing the length of
the outlet tube increases the back pressure at the pump head, particu-
larly when pumping viscous fluids.

Keep the inlet and outlet tubes as short as possible.

FIG. 4.6 WIRING DIAGRAM - FIXED TIMERS

CAUTION: PROPER EYE AND SKIN PROTECTION MUST BE WORN

WHEN INSTALLING AND SERVICING THE PUMP

Earth Ground (green)

120VAC

HOT
LOAD

220/230 VAC

Hot

Power
Cord

AC
MOTOR

Timer
Board

Neutral
Hot

Cycle Adjustment
Potentiometer

Common


C-600