4.2
Electrical Connections
Be certain to connect the pump to the proper supply voltage.
Using the incorrect voltage will damage the pump and may result in
injury. The voltage requirement is printed on the pump serial label.
Note: When in doubt regarding your electrical installation,
contact a licensed electrician.
The metering pump is supplied with a junction box for field wiring.
JUNCTION BOX MODELS -To reduce the risk of electric shock,
be certain that a grounding conductor is connected to the green
grounding screw located in the junction box.
FIG. 4.5 WIRING DIAGRAM - STANDARD MODELS
AC
MOTOR
INPUT
VOLTAGE
115V 60Hz
HOT
LEADWIRE
NEUTRAL
LEADWIRE
GROUND
LEADWIRE
230V 60Hz
BLUE or YELLOW*
BLUE
BROWN
RED
GREEN
GREEN
GREEN
MOTOR LEADWIRES
Neutral
Hot
Ground (green)
Earth Ground (green)
Common
Hot
AC
Input
Power
220V 50Hz
BLACK or YELLOW*
BLACK or YELLOW*
* Yellow leadwire : thermally protected motor
Black or Blue leadwire: standard impedance protected motor
24V 60Hz
WHITE
GREEN
BLUE*