8. RS232 / RS485
Command Structure.
Viewing data from the Multiflow;
All data is sent and received as ASCII HEX pairs, the maths used in PIC Hex format, 2 example routines are
included to convert this data into PC or ASCII strings. The PIC Hex format is always 4 bytes and represents a
32-bit floating-point number system. To read data use the following format.
Description ID
View
Hub/Slot
Reg/Mem Slot Address No.Bytes CR
String a
V
H R
00A0 04
CR
Hex 61
56
48
52
00A0
04 0D
ASCII Hex
36 31
35 36 34 38
35 32
30 30 41 30 30 34
0D
Notes: Reg/Memory allows the user to view live data within the Processors own working registers or the Flash
memory address space that is used to store constant and curve data. The Hub is the main processor (the card
connected to the serial link), whilst the SLOTs need to be addressed as follows.
Description ID
View
Hub/Slot
Reg/Mem Slot Address No.Bytes CR
String a
V
S M
04
0600 04
CR
Hex 61
56
49
4D 04
0600
04 0D
ASCII Hex
36 31
35 36 34 39
34 44
30
34
30 36 30 30 30 34
0D
SLOT ID
Hex Ascii Hex
Position
4
04 30 34
1A
5
05 30 35
1B
6
06 30 36
1C
7
08 30 38
2A
8
09 30 39
2B
9
0A 30 41
2C
10
0C 30 43
3A
11
0D 30 44
3B
12
0E 30 45
3C
13
10 31 30
4A
14
11 31 31
4B
15
12 31 32
4C
16
14 31 34
5A
17
15 31 35
5B
18
16 31 36
5C
General Address.
To obtain the list address for your instrument please send email to
to request a complete list,
also included are the conversion routines of the PicHex to standard PC/Ascii data.
Char output FAST MEDIUM or SLOW
Computer interface information
Port Settings.
The display shows menu ‘SETUP COMMS’, press ALTER to select the possible sub menus
BAUD
19200
Baud rate change using ALTER to 9600, 1200 or 19200
READ
ONLY
At present the system is set to read only
ID
a
Use ALTER to scan Ids a to z lower case only
RS485
FAST
Delay for bus transceiver FAST MEDIUM or SLOW
COMMS
FAST
Delay between Char output FAST MEDIUM or SLOW