Troubleshooting guide – Badger Meter Positive Displacement User Manual
Page 14

14
TROUBLESHOOTING GUIDE
TROUBLE
POSSIBLE CAUSE
SOLUTION
Meter indicates
lower than actual
x Viscosity of fluid is
<30cSt
x Excessive pressure
differential across meter
causing gears to bind
x Debris in measuring
chamber
x Upper housing has dimple
from over tightening
sensor
x Decrease the K-factor by
percent error
x Reduce flow rate, reduce
fluid viscosity
x Clean meter, change or
add filter
x Replace upper housing
Meter indicates
higher than
actual
x Air in lines
x Electro-magnetic
interference
x Reverse fluid flow
x Add air eliminator
x Ground flow meter and
all electronics
x Add check valve
Indicator shows
flow when there is
no flow
x Fluid oscillates
x Electro-magnetic
interference
x Check pump, add check
valve, increase back
pressure
x Ground flow meter and
all electronics. Use
shielded cable and
relocate away from
electrical noise.
- BEACON Advanced Metering Analytics (AMA) (2 pages)
- GALAXY (16 pages)
- GALAXY (20 pages)
- GALAXY (28 pages)
- ORION Cellular Endpoint (2 pages)
- ORION Cellular Endpoint (32 pages)
- ORION Cellular Endpoint (80 pages)
- ORION Migratable (ME) (96 pages)
- ORION Migratable (ME) (72 pages)
- ORION Migratable (ME) (60 pages)
- ORION Classic (CE) (2 pages)
- ORION Classic (CE) (20 pages)
- ORION Classic (CE) (2 pages)
- ORION Classic (CE) (28 pages)
- ORION Classic (CE) (8 pages)
- ORION Classic (CE) (16 pages)
- ORION Classic (CE) (32 pages)
- ORION Classic (CE) (20 pages)
- ORION Classic (CE) (28 pages)
- ORION Fixed Network (SE) (4 pages)
- ORION Fixed Network (SE) (48 pages)
- ORION Migratable (ME) (48 pages)
- ORION Migratable (ME) (2 pages)
- ORION Migratable (ME) (32 pages)
- ORION Migratable (ME) (20 pages)
- E-Series Ultrasonic Meters (2 pages)
- E-Series Ultrasonic Meters (12 pages)
- M-Series M2000 (24 pages)
- M-Series M2000 (2 pages)
- M-Series M2000 (4 pages)
- M-Series M2000 (60 pages)
- M-Series M3000 (40 pages)
- M-Series M4000 (36 pages)
- M-Series M5000 (36 pages)
- M-Series M5000 (4 pages)
- M-Series Field Verification Device (24 pages)
- Recordall Disc Series Meters (4 pages)
- Recordall Turbo Series Meters (20 pages)
- Recordall Transmitter Register (RTR) (2 pages)
- Industrial Turbo (16 pages)
- Water Conditioning (16 pages)
- Recordall Compound Series Meters (2 pages)
- Recordall Compound Series Meters (20 pages)
- Recordall Compound Series Meters (16 pages)
- Remote Electronic Display (RED) (8 pages)