Troubleshooting guide, Repair kit information, Troubleshooting guide 8 – Badger Meter 900 User Manual
Page 8: Repair kit information 8

TROUBLESHOOTING GUIDE
Trouble
Possible Cause
Remedy
No indication on register
• Debris in measuring chamber
• Broken magnet in magnetic drive
• Broken teeth on drive or driven gear
• Broken gears or shaft in register assembly
• Disassemble meter, clean out debris and
inspect for worn parts
• Replace magnetic drive
• Replace gear(s)
• Replace register
Low flow indication
• Flow rate is too low
• Bypass valves are leaking
• Increase flow above minimum rated gpm
• Close valves completely, repair or replace
High flow indication
• Gas in liquid
• Debris covering a portion of the
meter inlet
• Liquid is leaking around the inlet insert
• Install gas eliminator ahead of meter
• Remove meter from line and clean out debris
• Remove meter from line, remove insert and
reset with RTV
REPAIR KIT INFORMATION
Part Number
Repair Kit Description
B250-921
Complete Repair Kit; 42 Gallon Barrel; Low Range
B250-925
Complete Repair Kit; 42 Gallon Barrel; Mid Range
B250-923
Complete Repair Kit; 42 Gallon Barrel; High Range
B250-927
Complete Repair Kit; US Gallons
B250-931
Complete Repair Kit; Cubic Meters
B250-922
Repair Kit less Register; 42 Gallon Barrel; Low Range
B250-926
Repair Kit less Register; 42 Gallon Barrels; Mid Range
B250-924
Repair Kit less Register; 42 Gallon Barrels; High Range
B250-932
Repair Kit less Register; US Gallons
B250-928
Repair Kit less Register; Cubic Meters