TRACE
®
is a registered trademark of American Meter Company. Badger
®
, Recordall
®
, ORION
®
,
and RTR
®
are registered trademarks of Badger Meter, Inc. Itron
®
and ERT
®
are registered
trademarks of Itron, Inc. TORX
®
is a Registered trademark of Camcar, Division of Textron, Inc.
Hexagram
®
is a trademark of Hexagram, Inc. RAMAR
®
is a trademark of RAMAR Technology.
Other trademarks appearing in this document are the property of their respective entities.
© 2012 Badger Meter, Inc. All rights reserved.
Due to continuous research, product improvements and
enhancements, Badger Meter reserves the right to change
product or system specifications without notice, except to the
extent an outstanding contractual obligation exists.
Badger Meter
| P.O. Box 245036, Milwaukee, Wisconsin 53224-9536
800-876-3837 | [email protected] | www.badgermeter.com
PIT INSTALLATIONS
Insert the entire splice assembly into the filled splice tube P/N 62085-
001 as indicated in Figure 6. Close the cover with leads exiting alternate
sides as indicated in the drawing.
TESTING
After connections are complete, test the entire installation including the
RTR, wiring, and remote or pit module for proper operation in accordance
with the instructions supplied with the module.
Install the RTR on the water meter and secure it using the TORX
®
screw
provided.
TROUBLE SHOOTING
An analog ohm meter will show an "open" reading when connected
across the OUTPUT leads of the RTR. When operating the RTR, the
ohm meter should show a momentary deflection toward zero when the
RTR sends a signal.
Figure 6. Splice Enclosure Assembly
RTR
®
with three wires (brown cable)
For connection to ORION
®
Transmitter, Hexagram
®
Star Module or RA-
MAR
®
V4 Transpondit, verify the RTR has a brown cable and contains
a label with either an 'HE' for connectivity to Hexagram or an 'RA' for
connectivity to RAMAR. Using the chart below, connect the RTR con-
ductors to the AMR module conductors using insulation displacement
gel-filled splices, P/N 59761-001 provided in the installation kit. Crimp
the cables completely using a parallel jaw crimper, P/N 59983-001.
For connection to an Itron
®
remote ERT
®
, verify that the RTR has a brown
cable and contains an 'IT' on the label. For more information on the
installation instructions for the Itron remote ERT, please refer to Itron's
Installation Remote ERT Modules 40W-1 and 50W-1.
Figure 4. 3 Conductor RTR Splice Installation Diagram
Hexagram
Itron
RTR
ORION
Ramar V4
Pit/Remote
Remote
Red Red Wire
#2
Red Red
Black Black Wire
#3
Black Black
Green Green Wire
#1 White Green
If the wire is cut or broken and requires a field splice after initial
installation, connect like colors to maintain proper installation.
Place the two plastic cable ties P/N 34776-001 on wires and tighten
securely for strain relief. Remove excess cable tie with wire cutting
device.
CABLE TIES
(Remove Excess)
GEL-SPLICE
Figure 5. Splice Installation Diagram