Factory default settings – Thermo Fisher Scientific Eutech DO 6 Plus User Manual
Page 39

Instruction Manual
DO 6+
- 33 -
9. FACTORY DEFAULT SETTINGS
MENU DESCRIPTION
OPTIONS DEFAULT
COF.1
Configuration Setup Menu
A.ATC
Automatic Temperature Compensation
YES / NO
YES
b.DO
DO Concentration Units
mg/L or ppm
mg/L
CAL.2
Calibration Data
View only
_ _ _ _
ELE.3
Electrode Data Menu
FACT
Electrode Slope Factor
View only
1.000
OFS
Viewing the % Saturation offset
adjustment.
View only
0.0%
HI.mV
View mV Value at 100% Saturation
View only
50 mV
LO.mV
View mV Value at 0% Saturation
View only
0 mV
AtO.4
Automatic Power Off
YES / NO
YES
rSt.5
Reset to Factory Default Menu
A.CAL
Selection of Calibration Reset
NO / YES
NO
b.USR
Selection of User Reset
NO / YES
NO
OFS.6
% Saturation Offset Adjustment
+/- 10.0%
0.0%
DPr.7
Dissolved Oxygen Parameters Menu
A.HG
Pressure Adjustment in mm Hg
500 – 1499
760
A.PA Pressure
Adjustment
in kPa
66.6 - 199.9
101.3
b.SAL
Salinity Adjustment in ppt
0.0 - 50.0
0.0
Manual Temperature Compensation
0.0 - 50.0 °C
25.0°C
- PCTestr 35 (2 pages)
- pHScan BNC (3 pages)
- pHScan 3/3+ (5 pages)
- pHTestr 1 (3 pages)
- pHTestr 10/20/30/10 BNC/Spear (2 pages)
- ORPTestr 10/10 BNC (2 pages)
- EC/TDS/SaltTestr 11 (4 pages)
- EC/TDS/SaltTestr (2 pages)
- ECScan High/Low & TDScan High/Low (9 pages)
- SaltTestr (2 pages)
- EcoTestr pH 2 (2 pages)
- EcoTestr pH 1 (2 pages)
- EcoTestr EC High (2 pages)
- EcoTestr EC Low (2 pages)
- EcoTestr TDS High (2 pages)
- EcoTestr TDS Low (2 pages)
- EcoTestr Salt (2 pages)
- Eutech pH 5/6 Plus & Ion 6 Plus (New version R1.1, SN >797406) (23 pages)
- Eutech pH 5/6 Plus & Ion 6 Plus (Old version EP6, SN <797406, discontinued) (23 pages)
- Eutech COND/TDS/Salt 6 Plus (40 pages)
- EcoScan pH/Ion 5 & 6 (27 pages)
- EcoScan CON 6 & TDS 6 (56 pages)
- EcoScan CON 5 & TDS 5 (18 pages)
- EcoScan Salt 6 (40 pages)
- EcoScan DO 6 (80 pages)
- CyberScan pH 10/pH 100 (67 pages)
- CyberScan pH 11/pH 110 (76 pages)
- CyberScan CON 10/CON 100/CON 200 (62 pages)
- CyberScan CON 11/CON 110 (80 pages)
- CyberScan DO 110 (60 pages)
- CyberScan PCD 650 (127 pages)
- CyberScan CON 400/410 (For units manufactured before March 2010, discontinued) (60 pages)
- CyberScan CON 400 (For units manufactured from March 2010 onwards) (60 pages)
- CyberScan pH 300/310 (52 pages)
- CyberScan DO 300 (60 pages)
- CyberScan PC 300 (72 pages)
- CyberScan PD 300 (76 pages)
- CyberScan PC 10 (31 pages)
- C401 Colorimeter (64 pages)
- TN100 Turbidimeter (31 pages)
- RS232C Interface Adapter (9 pages)
- Thermo Scientific Temp 360 (44 pages)
- Thermo Scientific Temp 340 (40 pages)
- Thermo Scientific Temp 300 (32 pages)