Appendix b: troubleshooting, Software issues, Using pass mode – AMX Radia Eclipse 4-Channel Dimmer Module RE-DM4 User Manual
Page 87: Testing amx lighting features
![background image](/manuals/37053/87/background.png)
Appendix B: Troubleshooting
79
RE-DM4 and RE-DM6 RADIA Eclipse Dimmer Modules
Appendix B: Troubleshooting
Software Issues
The following items address software-related technical support issues and describe the steps necessary to use
NetLinx software in Terminal Emulator mode.
Using PASS mode
Use the PASS mode with a computer running capable of connecting to a NetLinx master controller, and the
AMX Lighting controller connected as an AxLink device.
Establishing communication with the master controller via terminal or Telnet:
1.
Type "show device /min
to determine the AxLink device number of the AMX Lighting controller.
2.
Enter Pass mode by typing "PASS" followed by the device number.
If the device number of the AMX Lighting controller were 96, you would type "PASS 96".
The whole typed enter pass mode command is PASS 96
key".
3.
The AMX Lighting controller returns the string ERXON in acknowledgment. If you do not get the pack,
you have not communicated or something else is wrong.
4.
The master controller returns Entering pass mode in acknowledgement.
5.
In order to exit pass mode, you must type ++
Testing AMX Lighting features
In general, any SEND_STRING valid for the Radia can be used in PASS mode. The ones below are a useful
subset.
If the master is version 3.21.343 or below, it does not yet have the Radia Eclipse
device name in its device table, so Radia Eclipse will show as "Unknown" in the list
returned.
Testing procedures for AMX Lighting features
To test this
Type this, then press Enter Result
Communications
1
Status of AMX Lighting channel 1
Curves
AC
Status of All Curves
AZ
Status of All Levels
AL100
All levels = 100%
AL0
All levels = 0
Channels
1L50T9
AMX Lighting channel 1 = 50%
2L50T9
AMX Lighting channel 2 = 50%
3L50T9
AMX Lighting channel 3 = 50%
4L50T9
AMX Lighting channel 4 = 50%
5L50T9
AMX Lighting channel 5 = 50%
6L50T9
AMX Lighting channel 6 = 50%
Low End Setting
LE?
Pack Status of Low End Trim
Ramping Up
AL100T20
Ramp all up in 20 sec.
Ramping Down
AL0T20
Ramp all down in 20 sec.
Phase Status
Y
Y-OK or Y-FAIL status is returned