2000 hz pulse output connections – Lake Monitors Flow Transmitters User Manual
Page 34
0-2000 Hz Pulse Output Connections
Wiring Instructions (Refer to Illustrations 6 and 7 above):
1) Move the programmable jumper on the circuit board into the
position closest to the meter’s inlet, as shown in Illustration 7.
2) Connect the positive voltage source (+12 to +35 VDC) to terminal
#1 of the din connector.
3) Connect terminal #2 of the din connector to the negative side
of the DC voltage source.
4) Connect the “G” terminal of the din connector to the pulse input
of the receiving device.
5) If the power source does not originate at the receiving device, a
wire will need to be connected between the negative side of the
voltage source and the signal ground of the receiving device.
6) If the transmitter is operating properly, the green LED on the circuit
board will illuminate brightly when power is applied to the unit.
Page 34 / Flow Transmitters / Lake Manual
Illustration 6
Illustration 7
PROGRAMMABLE JUMPER
IN POSITION CLOSEST
TO METER INLET
JUMPER POSITION - 0-2000Hz PULSE OUTPUT
NO CONNECTION
ELECTRICAL CONNECTIONS - 0-2000Hz OUTPUT
“G” PIN
0-2000Hz OUTPUT
PIN #1
+12 - 35 VDC
PIN #2
DC GROUND