Page 8
― 6 ―
Open Circuit
Voltage(DC)
Short Circuit
Current
Range
Accuracy
Greater than 4V
Greater than
200mA
20/200Ω
Auto-Ranging
Up to 2Ω
Over 2Ω
±(3%rdg+4dgt)
±(3%rdg+3dgt)
3. SPECIFICATION
Measurement Specification
Operating range(as in IEC61557) 20Ωrange:0.2Ω∼19.99Ω/200ΩRange:20Ω∼199.9Ω
Continuity (to IEC61557-4)
Insulation Resistance (to IEC61557-2)
Loop Impedance (to IEC61557-3)
RCD testing (to IEC61557-6)
Operating range(as in IEC61557) 20MΩ Range:0.5MΩ∼19.99MΩ/200MΩ Range:20MΩ∼100MΩ
Open Circuit
Voltage (DC)
500V +20%−0%
Rated Current
1mA or greater
@ 500kΩ
Range
20/200MΩ
Auto-Ranging
Accuracy
±(3% rdg +3dgt)
Rated Voltage
(AC)
230V+10%−15%
50Hz
Nominal Test
Current at 0Ω
External Loop
25A/10ms
15mA/350ms max.
Range
20Ω
2000Ω
Accuracy
±(3%rdg +8dgt)
±(3%rdg +8dgt)
Function
RCD × 1/2
RCD × 1
FAST
Rated Voltage
(AC)
230V+10%−15%
50Hz
Trip Current
Settings
10/30/100/300/
500mA
150mA
Trip Current
Duration
2000ms
50ms
Accuracy
Trip Current:
−8% ∼−2%
Trip Current:
+2% ∼+8%
Trip Time
±(1%rdg+3dgt)
Operating range(as in IEC61557) 20Ω Range:2Ω∼19.99Ω/2000Ω Range:100Ω∼1999Ω
Rated Voltage
100∼250V 50Hz
Measuring Range
100∼250V 50Hz
Accuracy
3%rdg
Voltage Measurement