― 5 ―

Over temperature protection

Detects overheating of the internal resistor
(used for loop and RCD tests) and of the
current control MOS FET (used for RCD
tests) displaying a warning symbol ( ) and
automatically halting further measurements.

Phase angle selector

The test can be selected from either the
positive (0

) or from the negative (180

) half-

cycle of voltage. This will prevent tripping of
some polarised RCDs when loop testing and
may give a more accurate reading when
testing RCDs.

Auto data hold

Holds the displayed reading for a time after
the test is complete.

Auto power off

Automatically switches the instrument off after
a period of approximately 1 minutes.

V-NE Monitoring Circuit

Automatically aborts measurement when the
N-E voltage rises to 50V or greater on RCD
ranges.

Optional Accessory

OMA DIEC distribution board or lighting circuit
test lead for LOOP/RCD testing.