Nozzles extending into tank

Caution:

Do not use nozzles that extend into the tank. This will block the emitted pulse.


Process connection
For the gauge to make accurate measurements:
• the tank process connection must be level.

• ensure a good fit with the gauge process connection

• the tank roof should not deform under the weight of the gauge



Discontinuities that influence the probe’s EM (electromagnetic) field

1 Agitator

2

Support beam perpendicular to the pulse
direction

3

Abrupt changes in tank cross section

4 Heating

tubes

5

Alternative solution: reference chamber -
electromagnetic field is contained within
chamber. See also notes in section.

6

Gauge electromagnetic field :
Any intruding metallic object will be
detected in this zone if perpendicular to
the emitted pulse direction.

= Do not fit the process connection near to these objects.