Installation and operating instructions BM 100 A


Power supply
Option 1

24 V DC / AC, +10%/-15%, Power used: 9W

Option 2

100 – 240 V AC, +10%/-15%, Power used: 9W

Process

Process temperature, flange

-30 to +150°C / -22°F to 298°F, option 200°C / 392°F
See BM100 A / Ai Supplementary Instructions for Ex values.

Process pressure, standard

-1 to +40 bar / -14.5 to +580 psig (higher on request)*
*Process pressure subject to the process temperature and the
mechanical properties of process connection

Dielectric constant

ε

r

: Measurement mode and probe type limits

Direct mode

Coaxial (D)

ε

r

≥ 1.4

twin probes (A,B,G&L)

ε

r

≥ 1.8

Level measurement

single probes (F,H&K)

ε

r

≥ 2.1

Level & interface measurement

Twin rod, coaxial & twin cable

ε

r

(interface) >>

ε

r

(level)

2

**

** The minimum layer is 100 mm / 4” and is dependant on the dielectric constant,

ε

r

. This has been

determined under test conditions using water (

ε

r

=80) and oil (

ε

r

=2.4). Please note that a layer less

than 100 mm / 4” will result in a level reading at a constant 100 mm / 4” above the displayed
interface level, also the interface level reading will be slightly higher than the true value.

TBF mode
Level measurement

All except D & G

ε

r

≥ 1.05

Human interface

KROHNE SMART and HART® protocols installed on first output.
Automatic recognition and configuration by gauge. Information
displayed via local display (integral or remote), PC or HART®
handheld communicator (HHC).
Point-to-point:

1 gauge connected to PC or HHC

Communication, standard

Multi-drop:

up to 15 gauges connected to PC or HHC

RS 485 (SMART): up to 255 per junction box with PC link

Fieldbus

PROFIBUS-PA: GSD

file

supplied with gauge.

Weight

Non-Ex/FM Housing

8 kg / 18 lb with DN50 PN10/16 flange

Ex/FM Housing

9 kg / 20.25 lb with DN50 PN10/16 flange

Single rod Ø10mm

0.62 kg/m / 0.83 lb/ft (twin rod or reverse: 1.24 kg/m / 0.83 lb/ft)

Single cable Ø4mm

0.12 kg/m / 0.08 lb/ft (twin cable Ø4mm : 0.24 kg/m /0.16 lb/ft)

Twin cable Ø6mm

0.28 kg/m / 0.19 lb/ft

Single cable Ø8mm

0.41 kg/m / 0.28 lb/ft

Coaxial Ø28mm

1.61 kg/m / 1.08 lb/ft

Standards


Electromagnetic Compatibility
Directive 89/336/EEC in conjunction with EN 61326-1(A1&A2).
EMC emissions shielding (with the exception of BM 100 As with
coaxial probes) is only guaranteed in metal tanks. Class A-
shielded as standard, class B shielding is available on demand.
Electrical equipment (low voltage)
Directive 73/23/CEE in conjunction with EN 61010-1.
ATEX

Electromagnetic Compatibility
and other protection directives
followed for EU countries

Refer to BM 100A/BM 100 Ai KEMA 01ATEX1078X
Supplementary Installation and Operating Instructions.