START-UP

18

OPTIWAVE 8300 C

www.krohne.com

02/2009 - 4000407102 - AD ATEX OPTIWAVE 8300 R02 en

Start-up

• Are the wetted components (gasket, flange and antenna) resistant to corrosion by the tank

product?

• Does the information given on the nameplate agree with the application?
• Did you connect the equipotential bonding system correctly?
• Ex d applications:

Ex d applications:

Ex d applications:

Ex d applications: Are the cable entries, plugs and adaptors Ex d-approved?

• Ex i applications:

Ex i applications:

Ex i applications:

Ex i applications: Are you using an intrinsic barrier within the correct parameters? Refer to the

"Ex i equipment" section. The electrical circuit characteristics must not be more than the
maximum intrinsically-safe values.

• Did you install the correct cable entries? Is the terminal compartment correctly sealed?
• Does the optional purging system agree with Ex requirements?

WARNING!
Make sure that it is safe to supply electrical power. Do a start-up check: