beautypg.com

Electrical connections – KROHNE OPTIWAVE 8300C Marine ATEX EN User Manual

Page 14

background image

3

ELECTRICAL CONNECTIONS

14

OPTIWAVE 8300 C

www.krohne.com

02/2009 - 4000407102 - AD ATEX OPTIWAVE 8300 R02 en

3.5.4 Electrical schema

Without an external sensor

Figure 3-2: Electrical schema for Ex i-approved equipment without an external sensor

1 Intrinsically-safe power supply (use second power supply for optional terminal 2)
2 Non-Ex zone
3 Ex zone
4 Resistor for HART

®

communication

With an external sensor

Figure 3-3: Electrical schema for Ex i-approved equipment with an external sensor

1 Intrinsically-safe power supply (use second power supply for optional terminal 2)
2 Non-Ex zone
3 Ex zone
4 Resistor for HART

®

communication

5 External sensor

=

=

AD_ATEX_OPTIWAVE8300_EN_090407_4000407102_R02_PRT.book Page 14 Tuesday, April 7, 2009 5:07 PM