3.5.2 Maximum intrinsically-safe values for the electrical circuit

Level transmitter without external sensor (output terminal 1 or 2)

• U

i

≤30 V

• I

i

≤300 mA

• P

i

≤1 W

• C

i

=30 nF

• L

i

=0.2 mH

Level transmitter with external sensor: output terminal 1

• U

i

≤30 V

• I

i

≤300 mA

• P

i

≤1 W

• C

i

=30 nF

• L

i

=0.2 mH

Level transmitter with external sensor: output terminal 2

• C

i

=0 nF

• L

i

=0 mH

3.5.3 Supply voltage

Level transmitter without external sensor

Level transmitter with external sensor

Current output terminal

Minimum voltage at output

terminal [VDC]

Maximum voltage at output

terminal [VDC]

1 (U

S1

)

14

1

30

1

2 (U

S2

)

2

10

1

30

1

1 for a current output of 22 mA
2 use a second power supply. This power supply energizes current output terminal 2 only.

Current output terminal

Minimum voltage at output

terminal [VDC]

Maximum voltage at output

terminal [VDC]

1 (U

S1

)

14

1

30

1

2 (U

S2

)

2

3

3

1 for a current output of 22 mA
2 use a second power supply. This power supply energizes current output terminal 2 only.
3 for more data, refer to the data sheet for the external sensor

AD_ATEX_OPTIWAVE8300_EN_090407_4000407102_R02_PRT.book Page 13 Tuesday, April 7, 2009 5:07 PM