Electrical connections – KROHNE OPTIWAVE 8300C Marine ATEX EN User Manual
Page 13
ELECTRICAL CONNECTIONS
3
13
OPTIWAVE 8300 C
www.krohne.com
02/2009 - 4000407102 - AD ATEX OPTIWAVE 8300 R02 en
3.5.2 Maximum intrinsically-safe values for the electrical circuit
Level transmitter without external sensor (output terminal 1 or 2)
• U
i
≤30 V
• I
i
≤300 mA
• P
i
≤1 W
• C
i
=30 nF
• L
i
=0.2 mH
Level transmitter with external sensor: output terminal 1
• U
i
≤30 V
• I
i
≤300 mA
• P
i
≤1 W
• C
i
=30 nF
• L
i
=0.2 mH
Level transmitter with external sensor: output terminal 2
• C
i
=0 nF
• L
i
=0 mH
3.5.3 Supply voltage
Level transmitter without external sensor
Level transmitter with external sensor
Current output terminal
Minimum voltage at output
terminal [VDC]
Maximum voltage at output
terminal [VDC]
1 (U
S1
)
14
1
30
1
2 (U
S2
)
2
10
1
30
1
1 for a current output of 22 mA
2 use a second power supply. This power supply energizes current output terminal 2 only.
Current output terminal
Minimum voltage at output
terminal [VDC]
Maximum voltage at output
terminal [VDC]
1 (U
S1
)
14
1
30
1
2 (U
S2
)
2
3
3
1 for a current output of 22 mA
2 use a second power supply. This power supply energizes current output terminal 2 only.
3 for more data, refer to the data sheet for the external sensor
AD_ATEX_OPTIWAVE8300_EN_090407_4000407102_R02_PRT.book Page 13 Tuesday, April 7, 2009 5:07 PM