ELECTRICAL CONNECTIONS

3

11

OPTIWAVE 8300 C

www.krohne.com

02/2009 - 4000407102 - AD ATEX OPTIWAVE 8300 R02 en

Electrical connections

3.1 General notes

3.2 Terminal compartment

3.2.1 How to open the terminal compartment

• De-energize the circuit.
• After the time given in the table that follows, remove the cover stop 1.

i

Use a 3 mm allen wrench.

• Remove the terminal compartment cover 2.

Time necessary to de-energize an Ex d [ia]-approved device

WARNING!

De-energize the circuit.

Use the applicable cable glands for the cable entry openings in the housing (Aluminium
housing: M26 x 1.5, M20 x 1.5, ½NPT or G½; Stainless steel housing: M25 x 1.5, M20 x 1.5,
½

NPT or G½). For the cable entry size, refer to the device nameplate.

If ambient temperature >60°C / >140°F, use heat-resistant cables and cable glands certified
for continuous operation above 90°C / 194°F.

Figure 3-1: How to open the terminal compartment

1 Cover stop
2 Terminal compartment cover

WARNING!
Do not remove the terminal compartment cover while the electrical power is connected.

Temperature class

Time to de-energize the Ex d [ia]-approved device

[minutes]

T6

20

T5

10

T4, T3

Not necessary