beautypg.com

7 technical data (extract) – KROHNE BM 700 EN User Manual

Page 18

background image

Page 18 BM 700 Installation and Operating Instructions

7 Technical data (extract)

Tank height (measuring range) 0.5 m to 20 m (1.64 ft to 65.6 ft)

Measuring accuracy (distance) from 1 m (3.3 ft): + 1 cm (0.4")

from 3.3 m (10.8 ft): + 0.3%

Measured-value resolution 1 mm (0.04")

Rate of change in level max. 10 m/min (33 ft/min) (tracking speed)

Connecting flanges

Horn antenna/Wave-Guide DIN 2501 DN 50 to DN 200 / PN 6 to PN 64 and higher;
Shape C to DIN 2526 or others
ANSI B16.5 2” to 8", Class 150 lbs or 300 lbs, RF
Wave-Stick Only DN 50...150 or ANSI 2”...6”, dairy DIN11851
DN50/65/80, Triclamp 2/3/4”, SMS 51/63/76 mm, G 1½ "

Max. allowable operating pressure -1 bar (14.5 psig) (vacuum) to max. 64 bar (928 psig) ,

depending on version and flange pressure rating. (see
name plate)

LP flange system with horn antenna, Wave-Guide or Wave-Stick without flange plate

2 bar

V96 flange system with Hornantenne or Wave-Guide:

Connection: nominal dia.

Flange rated pressure

PN 16

PN 25

PN 40

PN 64

DN mm

inches

bar

psig

bar

psig

bar

psig

bar

psig

80

3

16

232

---

---

40

580

64

928

100

4

16

232

---

---

38

551

55

797

150

6

16

232

---

---

34

493

47

681

200

8

16

232

25 bar

362

32

464

45

652

Wave-Stick: max. 16 bar (232 psig), temperature-dependent:

Temperature T

Pressure

-20

+150 °C

+100

-1

+1

+16

[bar]

46 - 0.3·T[°C] bar

-4

+212

+302 °F

-14

+14

+232

[psig]

745 - 2.42·T[°F] psig

Operating temperature LP flange system:

-20°C (-4°F) to +150°C (302°F)

at flange

V96 flange system:

(see also chapter 8)

Basic version:

-30°C (-22°F) to +130°C (266°F)

Special version:

min. - 60°C (-76°F)

High temp. version, FFKM: max. +250°C (482°F)

Kalrez 2035:

max. +210°C (410°F)

FPM (Viton) or FEP-coated: max. +200°C (392°F)

PTFE-Wave-Stick:

-20°C (-4°F) to + 150°C (302°F),

pressure depend

PP-Wave-Stick:

-20°C (-4°F) to + 100°C (212°F)