6

TECHNICAL DATA

34

OPTIMASS 1000

www.krohne.com

04/2011 - 4000977901 - MA OPTIMASS 1000 R01 en

ATEX (acc. 94/9/EC) temperature limits (standard)

ATEX (acc. 94/9/EC) temperature limits (T6)

OPTIMASS 1000 / 1010C with heating /

insulation

II 2 G Ex ib IIC T4…T1

Optional: II 2 G Ex ib IIC T6…T1

II 2 D Ex ibD 21 T175 °C

Optional: II 2 D Ex ibD 21 T165 °C

Ambient temp.
Tamb °C

Max. medium
temp. Tm °C

Temp. class

Max. surface
temp. °C

OPTIMASS 1000 / 1010C - with or

without heating jacket / insulation

65

89

T4

T130

130

T3 - T1

T175

OPTIMASS 1300C - aluminium converter

housing - no heating jacket / insulation

50

70

T4

T130

130

T3 - T1

T185

60

60

T4 - T1

T125

65

1

65

T4 - T1

T130

OPTIMASS 1300C- aluminium converter

housing - heating jacket / insulation

40

65

T4

T130

130

T3 - T1

T195

50

65

T4

T130

100

T3 - T1

T165

60

60

T4 - T1

T125

65

1

65

T4 - T1

T130

OPTIMASS 1300C - SS converter housing

- no heating jacket / insulation

50

70

T4

T130

130

T3 - T1

T185

55

55

T4 - T1

T120

OPTIMASS 1300C - SS converter housing

- heating jacket / insulation

40

65

T4

T130

120

T3 - T1

T185

50

65

T4

T130

75

T3 - T1

T140

55

55

T4 - T1

T120

1 depending on I/O option. Please call for more information.

Ambient temp.

Tamb °C

Max. medium
temp. Tm °C

Temp. class

Max. surface
temp. °C

OPTIMASS 1000 / 1010C T6 - with or

without heating jacket / insulation

40

45

T6

T80

60

T5

T95

95

T4

T130

130

T3 – T1

T165

50

60

T5

T95

95

T4

T130

130

T3 – T1

T165

65

95

T4

T130

130

T3 – T1

T165

MA_OPTIMASS_1000_en_110401_4000977901_R01.book Page 34 Friday, April 1, 2011 1:41 PM