Use a regular pattern to tighten the bolts evenly

3.4.5 Maximum pipework forces (end loadings)

Mass flowmeters have a maximum level of force (negative or positive) that can be applied to the
ends of the meter. Refer to the table below for permitted forces.

Maximum end loadings

• These (axial) loads have been calculated, based on 316L schedule 40 process pipework,

where un-radiographed butt welds have been used in pipe joints.

• The loads shown are the maximum permitted static load. If loads are cycling (between

tension and compression) these loads should be reduced. For advice, consult the
manufacturer.

S15

S25

S40

S50

Flanges

Flanges

Flanges

Flanges

20°C

40 barg

25kN

38kN

48kN

99kN

100 barg

17kN

19kN

15kN

20kN

130°C

32 barg

18kN

28kN

35kN

72kN

80 barg

12kN

12kN

7kN

8kN

Hygienic (all connections)

Hygienic (all connections)

Hygienic (all connections)

Hygienic (all connections)

130°C

10 barg

5kN

9kN

12kN

12kN