Factory fitted heating jacket
Factory fitted heating jacket
Factory fitted heating jacket
Factory fitted heating jacket
If the meter has been ordered with a heating jacket, it will be supplied with NPT, Ermeto or
flange connections.
Connecting / using the heating jacket
• Use reinforced flexible hoses to connect the heating jacket to the heat source.
• The heating jacket material is 316L but the heating medium is also in contact with the outer
cylinder, which might be a lower grade stainless steel.
• Suitable heating mediums are steam or hot oil. Avoid the use of heating mediums that can
cause crevice corrosion in Stainless Steel.
• Where liquid is being used, set up the pipe configuration so that air can be vented from the
system.
• Where steam is being used, set up the pipe configuration so that condensation can be drained
off.
• Heat the jacket to working temperature before flowing the process fluid through the meter.
Heating times
CAUTION!
The maximum heating pressure and temperature for heating jackets is 10 barg at
130°C / 145 psig at 266°F
Temperature [°C / °F] 1
Time [minutes]
15
25
40
50
40 / 104
15
60 / 140
45
80 / 176
75
100 / 212
135
120 / 248
480
1 Measured at the centre of the measuring tube.