3

INSTALLATION

24

OPTIMASS 1000

www.krohne.com

04/2011 - 4000977901 - MA OPTIMASS 1000 R01 en

Factory fitted heating jacket

Factory fitted heating jacket

Factory fitted heating jacket

Factory fitted heating jacket

If the meter has been ordered with a heating jacket, it will be supplied with NPT, Ermeto or
flange connections.

Connecting / using the heating jacket

• Use reinforced flexible hoses to connect the heating jacket to the heat source.
• The heating jacket material is 316L but the heating medium is also in contact with the outer

cylinder, which might be a lower grade stainless steel.

• Suitable heating mediums are steam or hot oil. Avoid the use of heating mediums that can

cause crevice corrosion in Stainless Steel.

• Where liquid is being used, set up the pipe configuration so that air can be vented from the

system.

• Where steam is being used, set up the pipe configuration so that condensation can be drained

off.

• Heat the jacket to working temperature before flowing the process fluid through the meter.

Heating times

CAUTION!
The maximum heating pressure and temperature for heating jackets is 10 barg at
130°C / 145 psig at 266°F

Temperature [°C / °F] 1

Time [minutes]

15

25

40

50

40 / 104

15

60 / 140

45

80 / 176

75

100 / 212

135

120 / 248

480

1 Measured at the centre of the measuring tube.

MA_OPTIMASS_1000_en_110401_4000977901_R01.book Page 24 Friday, April 1, 2011 1:41 PM