Key
Measuring mode
Menu mode
Data level
→
Go to the parameter setting mode, function 1.00.00
OPERATION. If access CODE 1 is activated, CODE 1 must be
entered first. Using function 3.07.02 access CODE 1 can be
activated or deactivated.
Go to the next, lower menu level. Go to the next character or change line
(only when 2 lines are displayed)
↵
Go to the error/Totalizer reset mode (via "CODE 2")
Return to the previous (higher)
menu level or leave the menu
mode.
Accept entered value
↑
Cycle through measured values, see Function 3.03.07 CYCL
DISP
Cycle through menu options
within actual menu level.
Cycle active digit up to new values
Function
Text
Description and settings
0.00.00 ERROR/TOT
Main
menu
0.00.00
0.00.01
VIEW ERR
View error messages list
0.00.02
RST ERR
Reset error messages
0.00.03
UP2 SW NO
Software version micro processor 2
0.00.04
DSP SW NO
Software version digital signal processor
0.00.05
DISPLAY
Display test, all display items on
0.00.06
EXIT
Leave menu 0.00
1.00.00
OPERATION
Main menu 1.00.00 Operation
1.01.00 FLOW
Submenu
1.01.00
Flow
1.01.01
FULL SCALE
Full-scale value for 100% volume flow rate, see Function 3.01.01
1.01.02
ZERO VALUE
Zero value, see Function 3.01.02
1.01.03
ZERO CAL
Zero calibration, see Function 3.01.03
1.01.04
MASTER TC
Master time constant, see Function 3.01.04
1.01.05
LF CUTOFF
Low-flow cut-off, see Function 3.01.05
1.01.06
CUTOFF ON
Cut-off active, see Function 3.01.06
1.01.07
CUTOFF OFF
Cut-off de-active, see Function 3.01.07
1.02.00 DISPLAY
Submenu
1.02.00
Display
1.02.01
DISP FLOW
Display of flow, see Function 3.03.01
1.03.00
PULSE OUTP
Submenu 1.03.00 Pulse output
1.03.01
PULSE RATE
Pulse frequency value for 100% scale, see Function 3.05.08
1.03.02
PULSE/UNIT
Pulse value per volume flow unit, see Function 3.05.09
2.00.00
TEST
Main menu 2.00.00 Test functions
2.01.00 DISPLAY
Submenu
2.01.00
Display
2.01.01 DISPLAY
Test display, lights all pixels. End with
↵ key
2.02.00 OUTPUTS
Submenu
2.02.00
Outputs
2.02.01
CURRENT
Test current output
0 mA
4 mA
12 mA
20 mA
22 mA
Use up arrow to advance. Displayed value directly present at current output. Actual value present at
output after pressing
↵ key.
2.02.02
PULSE
Test pulse/frequency output
1 Hz
10 Hz
100 Hz 1000 Hz
2000 Hz
Use the up arrow to advance. Displayed value directly present at Pulse output. Actual value present at
output after pressing
↵ key
2.03.00 INPUTS
Submenu
2.03.00
Inputs
2.03.03
DIG INPUT
Test digital input
Measure level at digital input. End with
↵ key.
2.04.00
DEV INFO
Submenu 2.04.00 Device information
2.04.01 MANUFACT
Display
manufacturer
2.04.02
MODEL NO
Display model number
2.04.03
SERIAL NO
Display serial number
2.04.04
UP2 HW NO
Display µP2 hardware number
2.04.05
UP2 SW NO
Display µP2 software number
2.04.06
FRNT HW NO
Display front end hardware number
2.04.07
DSP HW NO
Display D.S.P. hardware number
2.04.08
DSP SW NO
Display D.S.P. software number
2.04.09
TIME COUNT
Display time counter
3.00.00
INSTALL
Main menu 3.00.00 Installation
3.01.00
FLOW
Submenu 3.01.00 Volume flow parameters