Technical data – KROHNE OPTIFLUX 1000 EN User Manual
Page 27
TECHNICAL DATA
6
27
OPTIFLUX 1000
www.krohne.com
04/2014 - 4000846303 - HB OPTIFLUX 1000 R03 en
Materials
Sensor housing
DN10...40: malleable iron ( GTW-S-38-12)
DN50...150: sheet steel
Measuring tube
Austenitic stainless steel
Liner
PFA
Protective coating
On exterior of the meter: housing, signal converter (compact version)
and/or connection box (field version)
Polyurethane coating
Connection box
Only for remote versions
Standard: die-cast aluminium
Option: stainless steel
Measuring electrodes
Hastelloy
®
C
Grounding rings
Standard: for DN10...15 (integrated in flow sensor construction)
Optional: for DN25...150
Stainless steel 316 (1.4571) (AISI 316 Ti)
Grounding rings can be omitted with virtual reference option for the
IFC 300 converter.
Mounting material
DN40...150:
Standard: rubber centering sleeves
Option: galvanized steel or stainless steel stud bolts and nuts
Process connections
Process connections
Process connections
Process connections
Counter flanges
EN 1092-1
DN10...80: PN16 or PN40
DN100...150: PN16 (standard) PN40 on request
ASME
3/8...6" : 150 lb / RF
3/8...4" : 300 lb / RF
JIS
DN10...100: JIS 20K [≤ 16 bar] / DN150: JIS 10K [≤ 10 bar]
Electrical connections
For full detail; see the relevant documentation of the signal converter.
Signal cable ( for remote systems only)
Type A (DS)
In combination with the IFC 050, IFC 100 and IFC 300 signal converter
In combination with the IFC 050, IFC 100 and IFC 300 signal converter
In combination with the IFC 050, IFC 100 and IFC 300 signal converter
In combination with the IFC 050, IFC 100 and IFC 300 signal converter
Standard cable, double shielded.
Max. length: 600 m / 1950 ft
(depends on electrical conductivity and measuring sensor).
Type B (BTS)
Only in combination with the IFC 300 signal converter
Only in combination with the IFC 300 signal converter
Only in combination with the IFC 300 signal converter
Only in combination with the IFC 300 signal converter
Optional cable, triple shielded.
Max. length: 600 m / 1950 ft
(depends on electrical conductivity and measuring sensor).
I/O
For full details of I/O options, including data streams and protocols, see
technical datasheet of the relevant signal converter.