Flowmeter configuration

Parameter / Variable
(short description)

Name

Explanation

Relative
address

Absolute

address,

non-

Modicon

Absolute

address,

Modicon-

comp.

Units

Internal diameter

Diameter

Internal diameter of meter body at the measuring section.

1

7501

7502-7503

(2 regs)

m

Meter Constant forward

MeterConstant_Fwd

Meter constant, forward flow direction.

2

7502

7504-7505

(2 regs)

-

Meter Constant reverse

MeterConstant_Rev

Meter constant, reverse flow direction.

3

7503

7506-7507

(2 regs)

-

Thermal expansion factor pipe
material Alpha

ThermExp_Alpha_Pipe

Property of the material of the meter body, used to calculate
the effect of thermal expansion.

4

7504

7508-7509

(2 regs)

1/°C

Reference temperature Body
expansion

ThermExp_Reference-
Temp

Temperature at which the internal diameter of meter body at
the measuring section is specified.

5

7505

7510-7511

(2 regs)

°C

Channel Calibrated Path
Length L, channel 1-3

Ch_PathLength_Cal

Length of acoustic path length between two transducers of a
measuring path; array with values for channel 1 through 3.

6-8

7506-7508

(3 regs)

7512-7517

(6 regs)

m

Reserved

Reserved

Reserved

9-11

7509-7511

(3 regs)

7518-7523

(6 regs)

-

Channel Measuring Angle,
channel 1-3

Ch_Angle_Measuring

Angle at which the ultrasonic beam intersects with the meter
body; array with values for channel 1 through 3.

12-14

7512-7514

(3 regs)

7524-7529

(6 regs)

Deg

Reserved

Reserved

Reserved

15-17

7515-7517

(3 regs)

7530-7535

(6 regs)

-

Flow Full Scale Forward

Fwd_MaxFlowRate

Indicated value (full scale) at flow of 100% of rated volume
flow in forward flow direction

18

7518

7536-7537

(2 regs)

m

3

/s

Flow Full Scale Reverse

Rev_MaxFlowRate

Indicated value (full scale) at flow of 100% of rated volume
flow in reverse flow direction

19

7519

7538-7539

(2 regs)

m

3

/s

Low Flow cutoff Forward

Fwd_LowFlowCutoff

For forward flow rates with smaller magnitude than this cut-
off value, totalisers stop counting and outputs (such as the
frequency output) will be disabled; flow rate indication will still
be available

20

7520

7540-7541

(2 regs)

m/s

Low Flow cutoff Reverse

Rev_LowFlowCutoff

For reverse flow rates with smaller magnitude than this cut-
off value, totalisers stop counting and outputs (such as the
frequency output) will be disabled; flow rate indication will still
be available

21

7521

7542-7543

(2 regs)

m/s