COMMISSIONING / OPERATION

4

19

OPTIFLEX 2200 C

www.krohne.com

10/2013 - 4003066801 - MA OPTIFLEX2200C-PA-R01-en-

58

3

Converter ROM Error

Replace the signal converter.For more data, refer to the

handbook.

59

3

Sensor EEPROM Error

Replace the signal converter.For more data, refer to the

handbook.

60

3

Sensor RAM Error

Replace the signal converter.For more data, refer to the

handbook.

61

3

Sensor ROM Error

Replace the signal converter.For more data, refer to the

handbook.

63

3

Oscillator Frequency Failure

Replace the signal converter.For more data, refer to the

handbook.

64

3

Converter Voltage Error

Replace the signal converter.For more data, refer to the

handbook.

65

3

Sensor Voltage Error

Do a check of the power supply at the device terminals. Make sure

that voltage values are in the specified limits in menu item 2.2.2

DIAGNOSTIC (Configuration mode / Supervisor menu). If the

voltage is correct, replace the signal converter. For more data on

how to replace the signal converter, refer to the handbook.

66

3

Internal Communication Error

De-energize the device. Make sure that the signal cable engages

in the terminal and the screw connection is tight. Energize the

device. If the problem continues, replace the signal converter. For

more data, refer to the handbook.

67

3

Temperature Out of Range Error

Measure the ambient temperature. De-energize the device until

the ambient temperature is back in the given range. If the

temperature does not stay in the correct range, make sure that

there is insulation around the signal converter. If this error

occurs 2 times, replace the device.

68

3

Sensor not compatible

Go to menu 1.1.0 IDENT. in Configuration mode. Record the

version numbers of the device software given in menu items 1.1.2,

1.1.3 and 1.1.4. Give this data to the supplier.

72

3

Reference Lost Error

Speak to your supplier to make sure that the electronics are still

functioning correctly. Make sure that your installation has ESD

protection. For more data, refer to the handbook.

73

3

Level Lost Error

Measure the level of the contents in the tank using another

method of measurement. If the tank is empty (the level is below

the end of the probe), then fill the tank until product level is in the

measurement range. If the tank is full (the level is in the blocking

distance), then remove the contents from the tank until the level

is back in the measuring range. If the product was lost and the

tank is neither full nor empty, wait for the device to find the level

again.

If the device has to measure a product with εr≥1.6, refer to MEAS.

AMP. (Measured Pulse Amplitude, menu item 2.5.6) and then

adjust MEAS. THRESH. (measurement threshold, menu item

2.5.7). If the product has a low dielectric constant (εr<1.6) and the

device is in TBF mode, refer to PROBE END AMP (probe end pulse

amplitude, menu item 2.5.8) and then adjust PROBE END TH.

(probe end threshold, menu item 2.5.9). For more data, refer to

the handbook.

Make sure that the signal converter is correctly attached the

probe. For more data, refer to the handbook.

75

3

Overfill Error

Remove some of the product until the level is below the blocking

distance.

76

3

No Probe detected Error

Replace the signal converter.For more data, refer to the

handbook.