MODBUS PROTOCOL
6
13
MFC 300
www.krohne.com
11/2009 - 4000744801 - AD Modbus MFC 300 R01 en
6.8 Holding registers
Some parameters of the device can be accessed as Modbus holding registers.
Function code 03 (0x03) for "Read" operations and function code 16 (0x10) for "Write" operations.
The holding registers are grouped into the following different sections.
6.8.1 Counter parameters
INFORMATION!
Counter 3 parameters are only available for converter with IO2.
Modbus protocol
address
Description and settings
Converter
Fct. No.
Type
Number of
registers
40000
Counter 1 Function
Counter 1 Function
Counter 1 Function
Counter 1 Function
1 = Sum Counter
2 = + Counter
3 = - Counter
0 = Off
C4.1.1
byte
1
40001
Measurement Counter 1
Measurement Counter 1
Measurement Counter 1
Measurement Counter 1
21 = Volume Flow
22 = Mass Flow
27 = Concentration Flow 1
28 = Concentration Flow 2
C4.1.2
word
1
40002
Counter 2 Function
Counter 2 Function
Counter 2 Function
Counter 2 Function
1 = Sum Counter
2 = + Counter
3 = - Counter
0 = Off
C4.2.1
byte
1
40003
Measurement Counter 2
Measurement Counter 2
Measurement Counter 2
Measurement Counter 2
21 = Volume Flow
22 = Mass Flow
27 = Concentration Flow 1
28 = Concentration Flow 2
C4.2.2
word
1
40004
Counter 3 Function
Counter 3 Function
Counter 3 Function
Counter 3 Function
1 = Sum Counter
2 = + Counter
3 = - Counter
0 = Off
C4.3.1
byte
1
40005
Measurement Counter 3
Measurement Counter 3
Measurement Counter 3
Measurement Counter 3
21 = Volume Flow
22 = Mass Flow
27 = Concentration Flow 1
28 = Concentration Flow 2
C4.3.2
word
1
41000
Low Flow Cutoff Value Counter 1
Low Flow Cutoff Value Counter 1
Low Flow Cutoff Value Counter 1
Low Flow Cutoff Value Counter 1 [m
3
/s]
or [kg/s]
C4.1.3
float
2
41002
Time Constant Counter 1
Time Constant Counter 1
Time Constant Counter 1
Time Constant Counter 1 [s]
C4.1.4
float
2
41004
Set Counter 1 or Read Counter 1
Set Counter 1 or Read Counter 1
Set Counter 1 or Read Counter 1
Set Counter 1 or Read Counter 1 [m
3
] or [kg]
C4.1.7
float
2
41006
Low Flow Cutoff Value Counter 2
Low Flow Cutoff Value Counter 2
Low Flow Cutoff Value Counter 2
Low Flow Cutoff Value Counter 2 [m
3
/s]
or [kg/s]
C4.2.3
float
2
41008
Time Constant Counter 2
Time Constant Counter 2
Time Constant Counter 2
Time Constant Counter 2 [s]
C4.2.4
float
2
41010
Set Counter 2 or Read Counter 2
Set Counter 2 or Read Counter 2
Set Counter 2 or Read Counter 2
Set Counter 2 or Read Counter 2 [m
3
] or [kg]
C4.2.7
float
2
.book Page 13 Tuesday, November 24, 2009 1:48 PM