CAPAFLUX IFM 5080 K/CAP-EEx and CAPAFLUX IFM 5080 K/CAP i-EEx

9

2.4

Regular IFC 090 / CAP-EEx electronics unit

The field cables that enter the terminal compartment of the IFC 090 / CAP-EEx signal converter unit (i.e.
power supply, current and binary outputs) are non-intrinsically safe. To connect external devices to the
signal output terminals, the wiring requirements for the type of protection of the compartment (standard:
increased safety "e", optional: flameproof "d") must be conform to the international or national standard
involved (e.g. EN 60079-14).
The terminal arrangement is shown below.


Terminal arrangement in terminal compartment

pulse and status

outputs or
control inputs










100 - 240 V AC / 48 - 63 Hz


24 V AC / DC


PE Protective

ground

FE Functional

ground


Passive pulse/status output

Active current output





I

≤ 150 mA







eiectronic
or electro-
mechanical
totalizer





I

≤ 150 mA



U

ext

≤ 32 V DC

≤ 24 V AC



e.g.
signal
indicator










R

i

≤ 500 Ω

Note

The binary outputs (terminals B1, B

⊥ and B2) can only be configured as passive outputs,

the current output (terminals I+ and I) can only be configured as active output.

binary

outputs

current