Installation instructions VARIFLUX 6000

6 Limits

Max. operating pressure in bar (psig) at product temperature of …

Size of connections

Type of connections

mm inch

Pressure rating
of connections

< 40 °C
(< 104 °F)

< 100 °C
(< 212 °F)

< 120 °C
(< 248 °F)

< 140 °C
(< 284 °F)


DN 10* - 40

PN 40

40

(580)

40

(580)

40

(580)

40

(580)

DN 50 - 80

PN 25

25

(360)

25

(360)

25

(360)

25

(360)

DN 100

PN 16

16

(230)

16

(230)

16

(230)

16

(230)

Aseptic weld on for pipes * *
to DIN 11850

DN 125 - 150

PN 10

10

(145)

10

(145)

10

(145)

10

(145)

12* - 37.6

0.47* - 1.48

PN 40

580 psig

40

(580)

40

(580)

40

(580)

40

(580)

48.6 - 72.9

1.91 - 2.87

PN 25

360 psig

25

(360)

25

(360)

25

(360)

25

(360)

97.6

3.84

PN 16

232 psig

16

(230)

16

(230)

16

(230)

16

(230)

Aseptic weld on for pipes
to ISO 2037

110.3 - 135.7

4.34 - 5.34

PN 10

145 psig

10

(145)

10

(145)

10

(145)

10

(145)

DN 10* - 40

PN 40

40

(580)

40

(580)

40

(580)

40

(580)

DN 50 - 80

PN 25

25

(360)

25

(360)

25

(360)

25

(360)

DN 100

PN 16

16

(230)

16

(230)

16

(230)

16

(230)

Dairy screw to DIN 11851

DN 125 - 150

PN 10

10

(145)

10

(145)

10

(145)

10

(145)

Screwed to SMS 1145

25 - 100

PN 6

6

( 90)

6

( 90)

6

( 90)

6

( 90)

DN 25 - 40

PN 40

40

(580)

40

(580)

40

(580)

40

(580)

DN 50 - 80

PN 25

25

(360)

25

(360)

25

(360)

25

(360)

DN 100

PN 16

16

(230)

16

(230)

16

(230)

16

(230)

Flanges to DIN 11864-2A

DN 125 - 150

PN 10

10

(145)

10

(145)

10

(145)

10

(145)

12* - 51

1½” - 2.0”

PN 16

232 psig

16

(230)

16

(230)

16

(230)

63.5 - 76.1

2½” - 3.0”

PN 10

145 psig

10

(145)

10

(145)

10

(145)

100

4”

PN 8

115 psig

8

(115)

8

(115)

8

(115)

Clamp joint to ISO 2852

125 - 150

5” - 6”

PN 5

72 paig

5

( 72)

5

( 72)

5

( 72)

DN 25 - 50

PN 16

16

(230)

16

(230)

16

(230)

16

(230)

Clamp joint to DIN 32676 * *

DN 65 - 100

PN 10

10

(145)

10

(145)

10

(145)

10

(145)

25 - 80

1” - 3”

PN 20

280 psig

20.5

(295)

20.5

(295)

20.5

(295)

Clamp joint to TRI-CLOVER

100

4”

PN

12 174

psig 13.8 (200) 13.8 (200) 13.8 (200) – –

Vacuum load

all versions and sizes

all versions and

0 mbar abs. (0 psia)

pressure

ratings

*

for meter size size DN 2.5 - 10 /

1

/

10

” -

3

/

8

**

max. temperature are 150 °C (302 °F)

7 Grounding

Warning: All flowmeters must be properly grounded to avoid personnel shock hazard.

• The ground conductor should not transmit any interference voltages, therefore do not ground

any other electrical devices together with this conductor.

VARIFLUX 6000 compact systems

Supply power > 50 V AC
• Grounding is via the PE protective ground conductor incorporated in the power supply

cable, see also Section “Connection to power” in the installation and operating instructions for
the signal converter.

EXCEPTION: Do not connect up the PE protective ground conductor in the terminal box

if e.g. compact units are operated in the proximity of electric furnaces, electrolysis plants, etc.,
and large potential differences occur in the pipeline system. An FE functional ground must
simultaneously take over the function of the protective conductor (combined protective /
functional ground). Refer to appropriate national codes for specific requirements for this type
of installation, which may require the addition of a ground fault detection circuit interrupter.

Supply power 24 V AC or DC
• Protective separation (PELV) must be ensured (VDE 0100 / VDE 0106 or IEC 364 / IEC 536 or

equivalent national regulations).

• An FE functional ground conductor must be connected for measurement reasons.