Installation instructions VARIFLUX 6000

5


Strong electromagnetic fields, avoid in vicinity of flowmeter

Straight inlet run minimum of 5 × DN and outlet run minimum of 2 × DN,

(DN = meter size), measured from the electrode axis.

Vortex and corkscrew flow: increase length of inlet and outlet runs or install flow

conditioners.

Mixing different process liquids: install flowmeter upstream of mixing point or at an

adequate distance downstream (minimum of 30

× DN), otherwise display may be unsteady.

Insulated pipeline: do not insulate flowmeter.

Zero setting not necessary. To check, it should be possible to set “zero” flow velocity in the

completely filled measuring tube. Shutoff valves should therefore be provided either
downstream of the flowmeter or upstream and downstream of the flowmeter.

2

Suggestions for installation

To avoid measuring errors due to gas/air inclusion or to pipe running empty, please observe the
following:

Highest point of pipe run

Downpipe over 5 m (16 ft) length

(Air bubbles collect in measuring

Install air valve ✇ downstream of

tube - faulty measurements!)

flowmeter.






Pumps

Open feed or discharge

Never install flowmeter on pump suction side.

Install meter in low section of pipe.

open discharge

Downpipe
“Zero” flow
velocity.
Line drained.
Faulty
measurements!

Long pipeline
Always
install control and shutoff valves
downstream of flowmeter.

Preferred
locations

Horizontal pipe run
Install in slightly inclining pipe section. If not
possible, assure adequate velocity to prevent
air, gas or vapour from collecting in upper
part of flow tube.