4.4 Grounding and equipotential bonding
The manufacturer's measuring insert connections withstand a test voltage of 500 VAC to earth.
DANGER!
In order to prevent injury and material damage, always observe the following points regarding
grounding and equipotential bonding:
•
Always include the thermometer and its measuring insert as per EN 60079-14 in the
equipotential bonding of the installation site (when installed correctly, the fixing screws
guarantee this).
•
If the thermometer is not connected to a grounded metal pipe system or a container through
the process connection, you must include it in the equipotential bonding of the explosive area.
•
The connection for equipotential bonding is via the PA terminals or the process connection.
•
If there is a cable shield you must ground it according to EN 60079-14. A terminal in the
connection head means that the cable shield can be grounded by the shortest route.