beautypg.com

Device description – KROHNE OPTITEMP TCA Ex EN User Manual

Page 18

background image

2

DEVICE DESCRIPTION

18

OPTITEMP TRA/TCA

www.krohne.com

10/2010 - 4001087001 - Ex AD OPTITEMP TRA/TCA R02 en

2.7.5 Temperature at process connection for thermometers with connecting cable

Maximum permitted temperature at process connection for thermometers with connecting cable
in [°C]

Maximum permitted temperature at process connection for thermometers with connecting cable
in [°F]

DANGER!
The maximum permitted temperature at the process connection for all industrial thermometers
is T

P

= 400°C / 752ºF. The maximum permitted ambient temperature is T

a

= 70°C / 158°F. Always

refer to the table below!

DANGER!
Always refer to the tables below. Always use heat-resistant connecting cables if the temperature
at the process connection exceeds the values in the tables below.

Thermometer models

T

a

= 40ºC

T

a

= 55ºC

T

a

= 60ºC

T

a

= 65ºC

TxA-S11, threaded thermometer, neck pipe length ≤ 80mm

99

78

71

65

TxA-S12/41, threaded thermometer, neck pipe length ≥ 80mm

330

171

118

65

TxA-P10/40, insert thermometer with thermowell TxA-P10,
neck pipe length ≤ 80mm

157

102

83

65

TxA-P10/40, insert thermometer with thermowell, neck pipe
length ≥ 80mm

303

160

112

65

TxA-P14, insert thermometer without thermowell, neck pipe
length ≤ 80mm

157

102

83

65

TxA-P14, insert thermometer without thermowell, neck pipe
length ≥ 80mm

303

160

112

65

TxA-F13/42, flange thermometer, neck pipe length ≥ 80mm

364

184

124

65

Thermometer models

T

a

= 104ºF

T

a

= 131ºF

T

a

= 140ºF

T

a

= 149ºF

TxA-S11, threaded thermometer, neck pipe length ≤ 80mm

211

173

161

149

TxA-S12/41, threaded thermometer, neck pipe length ≥ 80mm

627

340

244

149

TxA-P10/40, insert thermometer with thermowell TxA-P10,
neck pipe length ≤ 80mm

316

215

182

149

TxA-P10/40, insert thermometer with thermowell, neck pipe
length ≥ 80mm

577

320

234

149

TxA-P14, insert thermometer without thermowell, neck pipe
length ≤ 80mm

316

215

182

149

TxA-P14, insert thermometer without thermowell, neck pipe
length ≥ 80mm

577

320

234

149

TxA-F13/42, flange thermometer, neck pipe length ≥ 80mm

688

364

256

149

.book Page 18 Friday, November 19, 2010 2:23 PM

This manual is related to the following products: