6.1.2 TT 60 C dimensions
Dimension [mm]
Dimension [inch]
1
44
1.73
2
27
1.06
3
7
0.28
4
33
1.30
Figure 11: TT 60 C dimensions
6.1.3 Data inputs and outputs
Bus connection
Bus connection
Bus connection
Bus connection
(terminals 6+7)
(terminals 6+7)
(terminals 6+7)
(terminals 6+7)
Sensor connection
Sensor connection
Sensor connection
Sensor connection
(terminals 1
(terminals 1
(terminals 1
(terminals 1----5)
5)
5)
5)
Communic
Communic
Communic
Communications connection
ations connection
ations connection
ations connection
U
i
:= V
max
30 VDC U
0
= Voc
30 VDC U
i
: = V
max
8.0 VDC
I
i
: = I
max
not limited I
0
= Isc
0.4 mA I
i
: = I
max
450 mA
P
i
: = P
max
not limited P
0
= Pt
6.5 mW P
i
: = P
max
800 mW
C
i
:
1 nF C
0
= Ca
1000 nF C
i
:
10 nF
L
i
10 µH L
0
= La
750 mH L
i
1 µH
Table 3: TT 60 C input/output electrical data
6.1.4 Ambient temperature data for areas with potentially explosive atmospheres, TT 60 C
Temperature class
Temperature class
Temperature class
Temperature class
Ambient temperature
Ambient temperature
Ambient temperature
Ambient temperature
T6
-40°C ≤ Ta ≤ +75°C
T5
-40°C ≤ Ta ≤ +85°C
T4
-40°C ≤ Ta ≤ +85°C
Tabelle 4: Temperature data, TT 60 C