beautypg.com

Values for input signals, tt 31 r, Attention, Table 2: inputs, tt 31 r – KROHNE OPTITEMP TT 31 R EN User Manual

Page 24

background image

02/2011 – 4000753501 – MA OPTITEMP TT31CR R01 en

www.krohne.com

24

6.1.4

Values for input signals, TT 31 R

Inputs 11-14, 21-24

(Intrinsically safe sensor connection)

U

o

:

≤ 15 VDC

I

o

:

≤ 13 mA

P

o

:

L

o

:

~ 100 mH

C

o

:

~ 550 nF

Table 2: Inputs, TT 31 R

ATTENTION!

The "Input/output/PC isolation" is galvanic isolation, comparable to a Zener barrier. The

TT 31 R can be supplied with an input voltage of <250 V using a non Ex-tested power

supply unit.