beautypg.com

Installation – KROHNE OPTIWAVE 5200 ATEX EN User Manual

Page 17

background image

INSTALLATION

2

17

OPTIWAVE 5200 C/F

www.krohne.com

04/2013 - 4001905802 - AD ATEX OPTIWAVE 5200 R02 en

Compact and Remote (Field) versions - PP and PFTE Wave Horn antennas
Equipment category 1/2 D, 2 D or EPL Da/Db, Db: Ex ia and Ex ia tb devices
Equipment category 3 D or EPL Dc: Ex ic devices

Flange

temperature

Ambient temperature

PP Wave Horn

PTFE Wave Horn and Wave-Stick

Compact version

Remote (Field)

version

Compact version

Remote (Field)

version

[°C]

[°F]

[°C]

[°F]

[°C]

[°F]

[°C]

[°F]

[°C]

[°F]

+80

+176

+80

+176

+80

+176

+80

+176

+80

+176

+90

+194

+75

+167

+75

+167

+76

+169

+76

+169

+100

+212

+70

+158

+71

+160

+72

+162

+71

+160

+110

+230

-

-

-

-

+68

+154

+67

+153

+120

+248

-

-

-

-

+63

+145

+62

+144

+130

+266

-

-

-

-

+59

+138

+58

+136

+140

+284

-

-

-

-

+55

+131

+54

+129

+150

+302

-

-

-

-

+51

+124

+49

+120

+160

+320

-

-

-

-

-

-

-

-

+170

+338

-

-

-

-

-

-

-

-

+180

+356

-

-

-

-

-

-

-

-

+190

+374

-

-

-

-

-

-

-

-

+200

+392

-

-

-

-

-

-

-

-

+210

+410

-

-

-

-

-

-

-

-

+220

+428

-

-

-

-

-

-

-

-

+230

+446

-

-

-

-

-

-

-

-

+240

+464

-

-

-

-

-

-

-

-

+250

+482

-

-

-

-

-

-

-

-