Installation – KROHNE OPTIWAVE 5200 ATEX EN User Manual
Page 16
2
INSTALLATION
16
OPTIWAVE 5200 C/F
www.krohne.com
04/2013 - 4001905802 - AD ATEX OPTIWAVE 5200 R02 en
Remote (Field) version (antenna housing only)
Equipment category 2 G or EPL Gb: Ex ia and Ex d ia devices
Equipment category 3 G or EPL Gc: Ex ic devices
Temperature
class
Maximum ambient temperature
Max. flange
temperature
PP Wave Horn
PTFE Wave Horn
Wave-Stick
Metallic Horn
(standard
temperature)
Wave Guide
Metallic Horn
(high-
temperature)
[°C]
[°F]
[°C]
[°F]
[°C]
[°F]
[°C]
[°F]
[°C]
[°F]
T6
+46
+115
+46
+115
+46
+115
+46
+115
+45
+113
+41
+106
+41
+106
+41
+106
+44
+111
+55
+131
+39
+102
+39
+102
+39
+102
+43
+109
+60
+140
T5
+54
+129
+54
+129
+54
+129
+59
+138
+75
+167
+43
+109
+43
+109
+41
+106
+55
+131
+100
+212
T4
+77
+171
+77
+171
+77
+171
+79
174
+85
+185
+70
+158
+71
+160
+70
+158
+77
+171
+110
+230
-
-
+55
+131
+53
+127
+72
+162
+135
1
+275
1
T3
-
-
+48
+118
+45
+113
+66
+151
+150
1
+302
1
-
-
-
-
-
-
+63
+145
+180
1
+356
1
-
-
-
-
-
-
+57
+135
+200
1
+392
1
T2
-
-
-
-
-
-
+53
+127
+250
1
+482
1
1 Make sure that gasket temperature is in the specified limits. For more data, refer to the handbook.
Temperature
class
Minimum ambient temperature
Min. flange
temperature
PP Wave Horn
Wave-Stick
PTFE Wave Horn
Metallic Horn
(standard
temperature)
Wave Guide
Metallic Horn
(high-
temperature)
[°C]
[°F]
[°C]
[°F]
[°C]
[°F]
[°C]
[°F]
[°C]
[°F]
T6...T2
-40
-40
-40
-40
-40
-40
-40
-40
-40
1
-40
1
-
-
-36
-33
-35
-31
-39
-38
-50
1
-58
1
-
-
-
-
-
-
-37
-34
-60
1
-76
1
1 Make sure that gasket temperature is in the specified limits. For more data, refer to the handbook.
INFORMATION!
Remote converter
Remote converter
Remote converter
Remote converter
The maximum ambient temperature, T
a
, permitted depends on the temperature class:
•
T
a
= +60
°
C for class T6
•
T
a
= +70
°
C for class T5
•
T
a
= +80
°
C for class T4