beautypg.com

Technical data – KROHNE OPTISWIRL 4070 Quickstart EN User Manual

Page 26

background image

4

TECHNICAL DATA

26

OPTISWIRL 4070

www.krohne.com

06/2010 - 4000122102 - QS OPTISWIRL R04 en

Process connections

Flange version

Flange version

Flange version

Flange version

DIN EN 1092-1

DN15...300 in PN16…100

ASME B16.5

½

...12" in 150…600 lb

JIS B 2220

DN15...300 in JIS 10…20 K

For detailed information on combination flange/pressure rating, refer to

chapter "Dimensions and weights".

Sandwich version

Sandwich version

Sandwich version

Sandwich version

DIN

DN15...100 in PN100 (higher pressures on request)

ASME

½

...4" in 600 lb (higher pressures on request)

JIS

DN15...100 in 10…20 K (higher pressures on request)

Electrical connections

Power supply

Non-Ex: 14…36 VDC

Ex: 14…30 VDC

Current output

Current output

Current output

Current output

Description of the used abbreviations

U

ext

= external voltage; R

L

= load + resistance

Measuring range

4...20 mA (max. 20.8 mA) + HART

®

protocol

Load

Minimum 0 Ω; maximum R

L

= ((U

ext

- 14 VDC) / 22 mA)

Error signal

Acc. to NAMUR NE43

Upper value: ≥ 21.0 mA

Lower value: ≤ 3.6 mA (not with HART

®

protocol)

Pulse output

Pulse output

Pulse output

Pulse output

Pulse rate

Max. 0.5 pulse/s (corresponds to 1800 pulses/hour)

Power supply

Non-Ex: 24 VDC as NAMUR or open < 1 mA, maximum 36 V, closed 100 mA,

U < 2 V

Ex: 24 VDC as NAMUR or open < 1 mA, maximum 30 V, closed 100 mA,

U < 2 V

HART

HART

HART

HART

®

HART

®

protocol via current output

Device revision

1

Physical layer

FSK

Device category

Transmitter, galvanically isolated

System requirements

Load min. 250 Ω

Multidrop operation

4 mA

Approvals and certifications

ATEX

ATEX II 2G Ex d ia [ia] IIC T6

FM

Class I, II, III

Div 1/2, groups A-G

QS_OPTISWIRL4070_R04_en_122102_PRT.book Page 26 Monday, June 7, 2010 8:51 AM