Technical data, Technical data 4.1 technical data – KROHNE OPTISWIRL 4070 Quickstart EN User Manual
Page 24
4
TECHNICAL DATA
24
OPTISWIRL 4070
www.krohne.com
06/2010 - 4000122102 - QS OPTISWIRL R04 en
Technical data
4.1 Technical data
INFORMATION!
•
The following data is provided for general applications. If you require data that is more
relevant to your specific application, please contact us or your local representative.
•
Additional information (certificates, special tools, software,...) and complete product
documentation can be downloaded free of charge from the website (Download Center).
Measuring system
Application range
Flow measurement of liquids, gases and vapours
Operating method / measuring principle
Karman vortex street
Measured value
Measured value
Measured value
Measured value
Primary measured value
Number of separated vortices
Secondary measured value
Operating and standard volumetric flow, mass flow
Signal converter
Signal converter
Signal converter
Signal converter
Versions
Compact
Option: Ex version
Measuring sensor
Measuring sensor
Measuring sensor
Measuring sensor
Standard
Basic device in flange version (with integrated temperature measurement)
Basic device in sandwich version (with integrated temperature
measurement)
Optional
Basic device with additional pressure measurement
Basic device with additional pressure measurement and shut-off valve for
pressure sensor
Dual measuring device in both flange and sandwich version (redundant
measurement)
Dual measuring device in flange version with additional pressure
measurement
Display and user interface
Display and user interface
Display and user interface
Display and user interface
Local display
2 lines, 10 characters per line
Operating and display languages
German, English, French
Measuring accuracy
Reference condition
Water at 20ºC
Air at 20°C and 1.013 bar abs.
Accuracy
Based on volume flow
Liquids
±
0.75% of measured value (Re ≥ 20000)
±
2.0% of measured value (10000 < Re < 20000)
Gases and steams
±
1.0% of measured value (Re ≥ 20000)
±
2.0% of measured value (10000 < Re < 20000)
Pressure and temperature compensation: ±1.5% of measured value (Re ≥
20000); ±2.5% of measured value (10000 < Re < 20000)
Repeatability
±
0.1% of measured value
Long-term stability
±
0.01% of measured value
QS_OPTISWIRL4070_R04_en_122102_PRT.book Page 24 Monday, June 7, 2010 8:51 AM