TECHNICAL DATA

7

35

VA40 - VA45

www.krohne.com

09/2013 - 4000424402 MA VA40 45 R04 en

Measuring ranges VA45

Reference condition for gas measurements:

Reference condition for gas measurements:

Reference condition for gas measurements:

Reference condition for gas measurements:
The flow measurement of gases are refered to
Nl/h or Nm

3

/h: Volume flow in Normal state 0°C, 1.013 bar abs. (DIN 1343)

SCFM or SCFH: Volume flow in Standard state 15°C, 1.013 bar abs. (ISO 13443)

Measuring span:

10 : 1

Declaration of flow::

Values = 100%

Air 20°C [68°F], 1.013 bar abs. [14,7 psia]

1 float form C
2 float form D
3 reading line

Cone no.

Float

form

Flow air

Max. pressure loss

[l/h]

[SCFH]

[mbar]

[psi]

DN15

N -15.01

C

1500...2300

55,8...85,6

3

0,044

D

2300…4800

85,6...179

3

0,044

N -15.02

C

5500…9000

205...335

3

0,044

D

9000…16000

335...595

3

0,044

DN25

N -25.01

C

3000…5000

112...186

3

0,044

D

5000…7500

186...279

3

0,044

N -25.02

C

7500…16500

279...614

3

0,044

D

16500…25000

614...930

4

0,058

DN40

N -40.01

C

17000…26000

632...967

4

0,058

D

26000…34000

967...1265

4

0,058

N -40.02

C

34000…60000

1265...2232

4

0,058

D

60000…75000

2232...2790

4

0,058

INFORMATION!
The operating pressure should be at least 5 times the pressure loss for gases! The specified
pressure drops are valid for water and air at maximum flow rate. Other flow ranges on request.
Conversion of other media or operating data (pressure, temperature, density, viscosity) is
performed using the calculation method in accordance with VDI /VDE Directive 3513