4.3.2 Limit switch settings MS14

• Untighten bracket screw 1 and set switching position
• Secure bracket screw 1

The distance between the limit switch and the casing is factory set with clamp screw 2 so that
the limit switch touches the glass taper at the maximum switching point.

The limit switch must be rotated 180° to reach the lower range of the scale.

4.3.3 Limit switch settings TG21

• Untighten bracket screw 1 and set switching position
• Secure bracket screw 1

The distance between the limit switch and the casing is factory set at approx. 1 mm (0.039") with
the clamping screw 2.