beautypg.com

Technical data, 2 technical data – KROHNE VA 40-VA 45 EN User Manual

Page 27

background image

TECHNICAL DATA

7

27

VA40 - VA45

www.krohne.com

09/2013 - 4000424402 MA VA40 45 R04 en

7.2 Technical data

INFORMATION!

The following data is provided for general applications. If you require data that is more
relevant to your specific application, please contact us or your local sales office.

Additional information (certificates, special tools, software,...) and complete product
documentation can be downloaded free of charge from the website (Download Center).

Measuring system

Application range VA40

Flow measurement of liquids, gases and vapors

Application range VA45

Flow measurement of gasses

Operating method / measuring principle

Variable area measuring principle

Measured value

Primary measured value

Float position

Secondary measured value

Operating and standard volumetric flow

Measuring accuracy

Directive

VDI / VDE 3513, sheet 2 (q

G

= 50%)

VA40

1.0%

VA45

2.5%

Operating conditions

Temperature

Temperature

Temperature

Temperature

Max. operating temperature

-20...+100°C / -4...+212°F

Pressure

Pressure

Pressure

Pressure

Max. permitted operating press. PS at TS = 100°C

Pressure equipment directive 97/23/ EC

Test pressure PT

Pressure equipment directive 97/23/EC

or AD 2000-HP30

VA40 - DN15, DN25

10 bar / 145 psig

1

VA40 - DN40

9 bar / 131 psig

1

VA40 - DN50

7 bar / 102 psig

1

VA45

1 bar / 14.5 psig

1

Installation conditions

Inlet run

≥ 5 x DN

Outlet run

≥ 3 x DN

1 other pressures upon request

MA_VA40_45_R04_en_424402_PRT.book Page 27 Monday, September 16, 2013 8:50 AM