TECHNICAL DATA

7

33

VA40 - VA45

www.krohne.com

09/2013 - 4000424402 MA VA40 45 R04 en

7.4 Measuring ranges

Measuring ranges VA40

Measuring span:

10 : 1

Declaration of flow:

Values = 100%

Water: 20°C [68°F]

Air: 20°C [68°F], 1.013 bar abs. [14.7 psia]

Float materials:

1 Stainless Steel or Hastelloy® - 2 PTFE with insert - 3 TFM - 4 Aluminium - 5 Polypropylene (PP)

Materials →

1

2

3

1

3

4

5

1

2

3

4

5

Cone ↓

Water [l/h]

Air [Nm3/h]

Max. pressure loss [mbar]

G 13.11

1

DN15

0.4

-

-

0.016

-

0.007

-

2

-

-

1

-

G 14.06

0.63

-

-

0.025

-

0.012

-

3

-

-

2

-

G 14.08

1

-

-

0.04

-

0.02

-

4

-

-

3

-

G 15.07

1.6

-

-

0.06

-

0.03

-

4

-

-

3

-

G 15.09

2.5

-

-

0.09

-

0.04

-

5

-

-

4

-

G 15.12

4

-

-

0.14

-

0.06

-

6

-

-

5

-

G 16.08

6.3

-

-

0.2

-

0.1

-

6

-

-

5

-

G 16.12

10

-

-

0.3

-

0.16

-

7

-

-

6

-

G 17.08

16

-

-

0.5

-

0.25

-

7

-

-

6

-

G 17.12

25

-

-

0.8

-

0.4

-

8

-

-

7

-

N 18.07

40

25

13

1.5

0.6

0.8

0.5

9

6

2

3

1

N 18.09

63

40

22

2.2 0.95

1.2

0.7

9

7

3

3

2

N 18.13

100

63

35

3

1.5

1.8

1.2

9

8

3

4

2

N 19.09

160

100

55

5

2.2

2.8

1.8

13

9

4

5

2

N 19.13

250

160

85

8

3.3

4.5

2.8

16

11

4

5

2

N 19.19

400

250

140

-

-

-

-

21

14

5

7

3

N 19.26

630

400

230

-

-

-

-

27

17

6

10

4

N 21.09

DN25

630

400

230

18

2

9

11

7

22

14

6

8

3

N 21.13

1000

630

350

28

2

14

18

12

23

17

6

8

4

N 21.18

1600

1000

600

49

2

-

28

2

17

2

26

25

7

10

6

N 21.25

2500

1600

950

70

2

-

42

2

26

2

33

40

8

12

9

N 41.09

DN40

1600

1000

600

45

22

28

18

32

18

9

11

5

N 41.13

2500

1600

900

70

2

36

45

2

28

2

34

20

10

12

5

N 41.19

4000

2500

1500

128

2

-

76

2

46

2

38

24

11

15

8

N 51.10

DN50

4000

2500

1500

120

2

56

70

45

43

25

12

15

7

N 51.15

6300

4000

2400

190

2

90

110

2

70

2

47

30

13

16

7

N 51.21

10000

6300

3500

310

2

-

170

2

118

2

55

42

14

20

10

1 reduced accuracy 2.5%
2 only possible with guided float

The oper. press. should be at least twice the pressure loss for liquids, and at least 5
times the pressure loss for gases! The specified pressure drops are valid for water and air at
maximum flow rate. Other flow ranges on request. Conversion of other media or operating data
(pressure, temperature, density, viscosity) is performed using the calculation method in
accordance with VDI /VDE Directive 3513

MA_VA40_45_R04_en_424402_PRT.book Page 33 Monday, September 16, 2013 8:50 AM