II — SPECIFICATIONS
The following specifications are at nominal input voltages
at 25°C, nominal output voltage ±1% unless otherwise
specified.
INPUT:
Voltage: 100-230V a-c nominal; Range 85-264V a-c
(0 to 100% load, 0 to 50°C); 110-370V d-c. (polar-
ity insensitive; consult factory) Safety agency
approval applies only to a-c input operation.
Frequency: Nominal 50-60 Hz; Range 47-400Hz (0
to 100% load, 0 to 50°C) (at 400Hz leakage cur-
rent exceeds UL/VDE safety specification limit).
Current (nominal output at 100% load):
@115V a-c rms: 4A a-c rms max.
5A a-c max for RMW 51212K-300
@230V a-c rms: 2A a-c rms max.
2.5A a-c max for RMW 51212K-300
Inrush Current (cold start 25 °C ambient, EMI
capacitors removed):
@115V a-c rms: 30A pk max.,
@230V a-c rms: 60A pk max.
Switching Frequency: 120KHz
POWER FACTOR:
@115V a-c: 0.99 typ. (0.96 for 12V and 15V model)
@230V a-c: 0.95 typ.
STABILIZATION:
Source Effect Range (±10% change in line voltage):
1% max.
Load Effect (±40% load change from 60% load):
Primary: ±1%
12V Aux: ±3%
+12V: ±5%
–12V:
±5% (RMW 51212K-300)
Ripple/Noise (all outputs, nominal line, rated load):
<1% Vp-p (measured with 15MHz BW scope ter-
minated with 0.047
µF and electrolytic capacitors.
CAPACITIVE LOADING: ≤ 30,000µF.
TRANSIENT RECOVERY:
Load change from 20% to 100% of rated output current in
50 microseconds or more: >700mV ±4% max.
OUTPUT HOLDING TIME: Upon input interruption
the output is maintained for: 20 mS typ. (@115V a-c, rated
load).
START UP TIME:
@115V a-c: 2S max.
@230V a-c: 2S max.
OVERVOLTAGE PROTECTION: Fixed, factory set.
See Table 2. Latching will occur. Reset by cycling input
power off, then on again.
OVERCURRENT: Hiccup type, autorecovery (output
voltage returns to rated level upon removal of cause of
overcurrent). Models RMW 5-60K and RMW 51212K-300
latch off for overcurrent or short circuit; reset by cycling
input power off, then on again.
OPERATING TEMPERATURE: 0 to +50°C (start up -
0°C min.). Do not allow the power supply to become dust
covered because that will decrease the cooling efficiency
of the unit and cause insulation to deteriorate.
STORAGE TEMPERATURE: –20°C to +85°C.
HUMIDITY: 10% to 95% RH, operating and storage,
noncondensing.
COOLING: Natural convection.
ALTITUDE: 3000 meters.
MOUNTING ORIENTATION: Vertical or horizontal.
EMC - EMISSIONS:
Radiated Noise 30MHz to 1GHz: FCC Class B,
CISPR 22 ‘B’
Conducted Noise 15KHz to 30MHz: FCC Class B,
CISPR 22 ‘B’
Input Harmonics (on AC Mains)
EN 61000-3-2, Class D.
EMC - IMMUNITY:
ESD: EN 61000-4-2 Criteria B (4KV contact, 8KV air
discharge)
Radiated Field Noise:
EN 61000-4-3 Criteria A (10V/M, 80% amplitude
modulation).
Electrical Fast Transient/Burst (EFT):
EN 61000-4-4 Criteria B (2KV).
Surge: EN 61000-4-5 Criteria B (1KV line to line 2KV
line to ground).
Conducted Noise:
EN 61000-4-6 Criteria A (10V/M, 80% amplitude
modulation).
Power Frequency Magnetic Field:
EN 61000-4-8 Criteria A (30A/meter).
Voltage Dips, Short Interruptions, Voltage Variation:
EN 61000-4-11
30% dips 10mS:
Criteria B
60% dips 100mS:
Criteria C
>95% dips 5000mS: Criteria C
SAFETY: Designed to meet UL 60950-1, CSA-22.2 No.
234, RMW 300W units are CE marked per the Low Volt-
age Directive (LVD), EN60950.
WEIGHT: 2.2 lbs. (1 Kg).