KEPCO Kit 219-0538, KLP Firmware Upgrade Kit (Version 7.xx to Version 8.xx) User Manual
Kepco, Klp firmware retrofit kit, Description

©2008, KEPCO, INC
1
Data subject to change without notice
228-1653
I N S T R U C T I O N M A N U A L
KLP
KEPCO
KEPCO, INC. " 131-38 SANFORD AVENUE " FLUSHING, NY. 11355 U.S.A. " TEL (718) 461-7000 " FAX (718) 767-1102
http://www.kepcopower.com " email: [email protected]
An ISO 9001 Company.
RETROFIT
KIT 219-0538
KLP
FIRMWARE RETROFIT KIT
1. DESCRIPTION
Kepco KIT 219-0538 contains the PROM used to upgrade the firmware for KLP 1200W power supplies from Ver-
sion 7.xx to Version 8.xx which offers the following improvements: a) baudrate is extended to 38500 (default), b)
simplified local configuration menu with added options, c) new fault recovery options, d) user-selectable remote
inhibit polarity, e) both standard (-1200) and LAN (-1.2K) models supported, f) original Operator Manual is replaced
by a CD that contains expanded KLP documentation, including a KLP Quick Start Manual, User Manual, Devel-
oper’s Guide and Labview and IVI drivers.
2. INSTALLATION INSTRUCTIONS
2.1 MATERIAL REQUIRED (SEE TABLE 1.)
2.2 DISASSEMBLY PROCEDURE
1. Disconnect all source power, load and programming cables from the power supply. If recently powered, allow
at least two minutes for the internal circuitry to discharge fully before removing the cover.
2. Note the serial number of the power supply on the nameplate located on bottom surface of the power supply
chassis.
3. Find a clean work surface with sufficient area to work on the power supply (an ESD-protected work surface is
ideal).
4. Place the wrist strap on your arm as indicated by the instructions for the wrist strap. Attach the clip to the power
supply's chassis. If the work surface is not ESD-protected, it is recommended that the chassis also be con-
nected to a known good ground potential. Do not use source power protective earthing connections
unless known to be zero potential.
5. Remove fourteen (14) flathead screws from the power supply cover: five (5) on each side surface and four (4)
on the top surface. Remove the cover by lifting it straight up. It may be necessary to apply a slight outward
force at the lower edge toward the rear of the power supply to release the cover. Set the cover and screws to
the side.
TABLE 1. MATERIAL REQUIRED
MATERIAL
LOCATION
QUANTITY
• PROM Replaces U7 on Circuit Card Assembly (CCA) A4
NOTE: PROMs are supplied preprogrammed with factory calibration
files and are identified by unit serial number on the device.
Provided in this Kit
1
• ESD (Electrostatic Discharge) wrist strap (Kepco P/N 114-0080)
Provided in this Kit
1
• PLCC PROM Extractor (Kepco P/N 114-0079)
Provided in this Kit
1
• Instruction Manual 228-1653
Provided in this Kit
1
• Documentation CD 254-0033
Provided in this Kit
1